5-7
SORGENTE/SMILE/ISI-T/UNDERCOUNTER - Installation, Use and Maintenance - cod. A-MAN03 - Rev. 02/2012
spanner (28mm) if a rechargeable bottle is used
(fig. 5.9)
,
in case a 600gr. monouse gas bottle is used, screw the reducer
on the bottle by hand.
Pay attention to do not lay the bottle during the pressure
reducer screwing phase. Position and fix the bottle in vertical
position.
Open the (rechargeable) gas bottle by turning the upper
handgrip counterclockwise
(fig. 5.10)
.
Turn clockwise the black knob of the pressure reducer
(screwing deeply towards the + sign) and check that there
are no leakages on the connection points by using soapsuds
water
(fig. 5.11)
.
fig.5.9
fig.5.10
fig.5.11
CAUTION
The dispenser Manufacturer declines
any responsibility for possible
damage to persons or things due
to connection of the dispenser
to electrical mains not in conformity
with the regulations and
laws in force in the country where
the device will be installed. In
particular, the electric mains to
which it will be installed must be
equipped with a high sensitivity
circuit breaker switch (cut-out
switch), with tripping power not
greater than 30mA, and a grounding
system in conformity with the
standards and regulations in force.