Install Operator
D. Install Power Module Sub-assemblies.
1.
Using three (3) #8-32 x 5/16" Phillips screws per
assembly, secure power module sub-assemblies
to backplate at location marked on backplates.
(Figure 15)
NOTE: Orient assemblies so LCD screens on
inverters are toward corresponding closer
assemblies. (Figure 15)
C. Install Conduit Assembly and wire to building.
1. Orient conduit assembly so two (2) conduit
holes are at bottom and text on wire input label
is legible. (Figure 13)
2. Secure assembly to backplate using four (4)
#8-32 x 5/16" Phillips head screws. (Figure 13)
WARNING: BUILDING POWER MUST BE OFF
BEFORE PROCEEDING!
3. Secure conduits to conduit assembly (surface or
concealed conduit). (Figure 14)
4. Wire building 120VAC to conduit assembly –
LINE, NEUTRAL, and GROUND. (See page 15 for
General Electrical Information.)
5. Wire 24VDC for accessories to conduit assembly
24VDC + / - as required. (See page 15 for General
Electrical Information.)
WARNING: DO NOT TURN ON BUILDING POWER
UNTIL DIRECTED TO DO SO! RISK OF INJURY OR
DEATH!
Figure 13