D6021/D6031 Double Unit Series
(Push Side) Power Operator
Double Door Fail Safe Electric Strike or Electromagnetic Lock 24VDC Wiring
Double Door 24VDC Electric Exit Device Wiring
Factory Pre-Wiring in Illustration is for this functionality
Change Factory Pre-Wiring to Illustration Below (move NO to NC)
•
For Master/Follow or
Master-Coord/Follow only
(Sync Cable must be used
to connect inverters.)
• Doors are normally closed
and latched.
• Activating switch will
energize exit device and
door will automatically
open. Exit device will
stay energized based on
Latch Rtrct setting. Door
will close after hold open
time delay has expired.
• Current draw at Power
Outputs not to exceed
1.3 amps.
•
For Master/Follow or
Master-Coord/Follow only
(Sync Cable must be used
to connect inverters.)
• Doors are normally closed
and latched.
• Activating switch will
unlock electric strike or
mag lock and door will
automatically open. Door
will close after hold open
time delay has expired.
• Door will remain
unlocked during power
failure.
• Current draw at Power
Outputs not to exceed
1.3 amps.