D6021/D6031 Double Unit Series

 (Push Side) Power Operator

Controller Interface Description

Screen 1

Adjustments

Default

Description

Mount:

Push or Pull

Push

Side of opening operator is mounted on

Hold Open:

0 - 30 sec in 1 sec increments

4s

Amount of time door will stay in full open position after an activation

Open Delay 

(previously Start 

Delay):

0 - 10 sec in 1 sec increments

0s

Time before operator begins to open door. This is to allow accessories time to 

function and not hinder the opening of the door.

Latch Rtrct:

OFF, 3 - 45 sec in 5 sec increments

OFF

Amount of time power is supplied to a latch retraction device.

Home:

see Setting Open Position

-

Used to set the Home position and the Fully Open position of the door.

Vestibule:

OFF, 5 - 30 sec in 5 sec increments

OFF

Amount of delay for opening 2nd vestibule door

Push:

OFF or PushNGo

OFF

Turn on or off Push N Go feature. If On, a slight push or pull of the door starts it 

automatically opening.

Open Speed:

0 - 100% in 1% increments

120

How fast the door opens to the full open position.

Close Speed:

0 - 100% in 1% increments

80

How fast the motor returns to the home position. As Latch and Sweep on the closer 

are adjusted, adjustments may be needed for Close Speed to assure closer is not 

trying to backdrive the motor.

Errors:

not adjustable

-

Error code seen by controller. See Page 16 for Controller Error Codes.

Screen 2

Adjustments

Default

Description

Door Feedback:

not adjustable

-

General feedback. Includes Door State, Door Position, Motor Position, Open Limit, 

Close Limit.

Drive Feedback:

not adjustable

-

General feedback. Includes Bus Voltage, Bus Current, Frequency.

Usage:

not adjustable

-

General feedback. Includes Open Time, Close Time, Days, Cycles, Firmware Rev.

Single:

Single Door, Dble:Follow, 

Dble:Master, Dble:Mast Coord

Single

Set on Single for a single, stand alone door. Dble:Follow for Follower door on pair 

of doors. Dble:Master for Master door on a pair of doors. Dble:Mast Coor for Master 

door on a pair of doors when door coordination is needed.

MastStopOffset:

0-500

180

Adjustable point where Master Coord door will stop and wait for Follower door to 

fully close so Follower does not contact astragal attached to Master Coord door.

PDET Option:

On, Off

Off

On or Off for 585 Presence Detector

DT:

Standard, SS1:Stall,

SS1:Return Open, SS1:Stall /

Open

Stnd

Standard is Door Toggle. SS1 is for use of a Closing side door presence detector. 

SS1:Stall - door stalls when obstruction is detected; SS1:Return Open - door 

reopens when obstruction is detected; SS1:Stall/Open - door stalls when 

obstruction is detected and then reopens when obstruction is removed.

A2:

Standard, SS2:Stall,

SS2:Return Home, SS2:Stall /

Home

Stnd

Standard is Activation mode - just like A1 activation. SS2 is for use of an Opening 

side door presence detector. SS2:Stall - door stalls when obstruction is detected; 

SS2:Return Home - door closes to home when obstruction is detected; SS2:Stall/

Home - door stalls when obstruction is detected and then returns home when 

obstruction is removed.

Rly2:

Alarm, Activation, On Opened, 

On Closed

Alarm

How Relay 2 is used: Alarm - used with above Alarm Delay; Activation - acts as an 

additional NO/NC contact; On Opened - relay trips (closed contacts) when door 

is in opened position; On Closed - relay trips (closed contacts) when door reaches 

the fully closed position.

Alarm Delay:

OFF, 30 sec, 60 sec

OFF

Used only for alarm accessories

Slow Speed:

0 - 100% in 1% increments

55

Speed up or slow down door during last few degrees of opening.

Hold Speed:

0 - 100% in 1% increments

55

Increase or decrease hold open force (when in “ON” position only, not “H/O”) to 

compensate for spring force, wind conditions, etc.

Obst Delay:

0 - 5 sec in 1 sec increments

3s

Obstruction Delay: the amount of time the operator will push against an 

obstruction before closing if during an opening cycle or reopening and trying to 

close again if during a clocking cycle.

Summary of Contents for Norton D6001BP-38-LH

Page 1: ...nverter 6000IN End Cap LH 6001ENLH Union Spacer 6001US Operator LAP 6021LAP Inverter 6000IN Power Supply 6000SUP Power Module Sub assembly 6001PM Closer Assembly 7500LAP Main Arm and Rod 6030 1W Adjus...

Page 2: ...cal Data 4 Prepare Frame and Doors 5 Install Operators 8 Install Track and Arm 11 Adjustments 12 Power Operators 13 Sync Operators 14 Finalize Installation 15 General Electrical Information 15 Wiring...

Page 3: ...thers required Closing When the hold open time has elapsed the door closer will close the door automatically The door will slow to low speed at latch before it reaches the fully closed position The do...

Page 4: ...ased on 1 8 gap between door and frame All dimensions are given in inches DO NOT scale drawings Thickness recommended for reinforcements in hollow metal doors and frames is charted This template infor...

Page 5: ...r shimming is required Failure to mount units properly can result in improper function of operator or inability to snap on covers 3 Mark center of opening on frame header between jambs 4 Using chart m...

Page 6: ...ing backplate as template mark conduit slot and Dim D mounting hole Figure 5 NOTE Dim D should be 5 16 up from bottom of frame header if backplate is properly aligned 7 Drill hole for mounting screw a...

Page 7: ...t to properly secure top edge of backplate Use of blocking supplied by others or shims provided to fill gap between backplate and wall above header is HIGHLY recommended Material must comply with loca...

Page 8: ...LAP so spring tube of closer is pointed toward closest hinge edge of frame Slide each LAP over two 2 screws and tighten Figure 11 NOTE When properly oriented spring tube is at bottom on left hand bac...

Page 9: ...embly so two 2 conduit holes are at bottom and text on wire input label is legible Figure 13 2 Secure assembly to backplate using four 4 8 32 x 5 16 Phillips head screws Figure 13 WARNING BUILDING POW...

Page 10: ...or Operator LAP 10 Pin Black Connector Operator LAP 3 Pin White Connector Power Module Sub assembly 3 Pin White Connector Power Module Sub assembly 10 Pin Black Connector Operator LAP 10 Pin Black Con...

Page 11: ...l two 2 1 4 20 x 1 5 8 screws through each shoe and into sex bolts Figure 19 NOTE Orient shoe with short side of shoe toward hinge Figure 20 View from ceiling looking downward Short Side of Shoe Hinge...

Page 12: ...reach nut remove Torx screw in end cap access door and slide door open When finished slide access door closed and reinsert 6 Torx flat head screw to secure door Figure 26 Adjustments A Adjust mechani...

Page 13: ...sh up or down on joystick Figure 27 To change setting of a menu item when cursor is on that item push joystick left right to increase decrease value NOTE Values will auto save 3 seconds after adjustme...

Page 14: ...o Single increase to Dbl Follower NOTE Dbl MasterCoord to be used when astragal or similar is attached to Master door or as a replacement for a mechanical door coordinator Once set Master Figure 29 Un...

Page 15: ...backplate verify backplate is not warped or twisted Additional support or shimming may be required See Sections A B under Prepare Frame and Door WARNING Make sure no wiring is loose or can be caught b...

Page 16: ...ce connected to Aux 1 is sending constant signal Aux 2 Stuck Activation device connected to Aux 2 is sending constant signal Aux 3 Stuck Activation device connected to Aux 3 is sending constant signal...

Page 17: ...mware Rev Single Single Door Dble Follow Dble Master Dble Mast Coord Single Set on Single for a single stand alone door Dble Follow for Follower door on pair of doors Dble Master for Master door on a...

Page 18: ...Function with Switches For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed Fail Secure Electric Strike 24VDC Wiring For Master Follow...

Page 19: ...to NC For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed and latched Activating switch will energize exit device and door will automa...

Page 20: ...osed Activating switch will open door Door will remain in indefinite hold open until activating switch is activated a second time causing door to close Change Factory Pre Wiring to Illustration Below...

Page 21: ...t be used to connect inverters Doors are normally closed and latched Fire Alarm activation will retract exit device latch bolt and door operator will open door Door will remain open until the Fire Ala...

Page 22: ...ed Activating wireless switch or hand held wireless transmitter will open door Door will remain in indefinite hold open until wireless switch or hand held transmitter is activated a second time causin...

Page 23: ...re normally closed and latched Activating outside door switch will open outside door After vestibule time delay has elapsed a signal will be sent to inside door which will open Activating inside door...

Page 24: ...eps 1 4 Hand Held Configuration depress push plate to activate transmitter 4 Attach transmitter to inside of electrical box and complete installation Removing Transmitter Code s Single Transmitter Cod...

Page 25: ...will close after hold open time delay has elapsed If door is closed and 585 Presence Detector senses something in opening door will not open If door is at open position and 585 Presence Detector sens...

Page 26: ...oller screen If DT is set to Standard this is normal Door Toggle mode and will not work with Presence Sensor set to Stall door closing will stall until presence not sensed set to Return Open presence...

Page 27: ...ing When door reaches open position door drifts further open Decrease Hold Speed on controller see page 17 until door stops drifting When door reaches open position door bounces Decrease Slow Speed on...

Page 28: ...d Reproduction in whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group Inc is prohibited 80 9360 1030 020 Rev 6 11 20 D 2 7 60 1 reveal 6 8 175 max...

Reviews: