D6021/D6031 Double Unit Series
(Push Side) Power Operator
Controller Interface Description
Screen 1
Adjustments
Default
Description
Mount:
Push or Pull
Push
Side of opening operator is mounted on
Hold Open:
0 - 30 sec in 1 sec increments
4s
Amount of time door will stay in full open position after an activation
Open Delay
(previously Start
Delay):
0 - 10 sec in 1 sec increments
0s
Time before operator begins to open door. This is to allow accessories time to
function and not hinder the opening of the door.
Latch Rtrct:
OFF, 3 - 45 sec in 5 sec increments
OFF
Amount of time power is supplied to a latch retraction device.
Home:
see Setting Open Position
-
Used to set the Home position and the Fully Open position of the door.
Vestibule:
OFF, 5 - 30 sec in 5 sec increments
OFF
Amount of delay for opening 2nd vestibule door
Push:
OFF or PushNGo
OFF
Turn on or off Push N Go feature. If On, a slight push or pull of the door starts it
automatically opening.
Open Speed:
0 - 100% in 1% increments
120
How fast the door opens to the full open position.
Close Speed:
0 - 100% in 1% increments
80
How fast the motor returns to the home position. As Latch and Sweep on the closer
are adjusted, adjustments may be needed for Close Speed to assure closer is not
trying to backdrive the motor.
Errors:
not adjustable
-
Error code seen by controller. See Page 16 for Controller Error Codes.
Screen 2
Adjustments
Default
Description
Door Feedback:
not adjustable
-
General feedback. Includes Door State, Door Position, Motor Position, Open Limit,
Close Limit.
Drive Feedback:
not adjustable
-
General feedback. Includes Bus Voltage, Bus Current, Frequency.
Usage:
not adjustable
-
General feedback. Includes Open Time, Close Time, Days, Cycles, Firmware Rev.
Single:
Single Door, Dble:Follow,
Dble:Master, Dble:Mast Coord
Single
Set on Single for a single, stand alone door. Dble:Follow for Follower door on pair
of doors. Dble:Master for Master door on a pair of doors. Dble:Mast Coor for Master
door on a pair of doors when door coordination is needed.
MastStopOffset:
0-500
180
Adjustable point where Master Coord door will stop and wait for Follower door to
fully close so Follower does not contact astragal attached to Master Coord door.
PDET Option:
On, Off
Off
On or Off for 585 Presence Detector
DT:
Standard, SS1:Stall,
SS1:Return Open, SS1:Stall /
Open
Stnd
Standard is Door Toggle. SS1 is for use of a Closing side door presence detector.
SS1:Stall - door stalls when obstruction is detected; SS1:Return Open - door
reopens when obstruction is detected; SS1:Stall/Open - door stalls when
obstruction is detected and then reopens when obstruction is removed.
A2:
Standard, SS2:Stall,
SS2:Return Home, SS2:Stall /
Home
Stnd
Standard is Activation mode - just like A1 activation. SS2 is for use of an Opening
side door presence detector. SS2:Stall - door stalls when obstruction is detected;
SS2:Return Home - door closes to home when obstruction is detected; SS2:Stall/
Home - door stalls when obstruction is detected and then returns home when
obstruction is removed.
Rly2:
Alarm, Activation, On Opened,
On Closed
Alarm
How Relay 2 is used: Alarm - used with above Alarm Delay; Activation - acts as an
additional NO/NC contact; On Opened - relay trips (closed contacts) when door
is in opened position; On Closed - relay trips (closed contacts) when door reaches
the fully closed position.
Alarm Delay:
OFF, 30 sec, 60 sec
OFF
Used only for alarm accessories
Slow Speed:
0 - 100% in 1% increments
55
Speed up or slow down door during last few degrees of opening.
Hold Speed:
0 - 100% in 1% increments
55
Increase or decrease hold open force (when in “ON” position only, not “H/O”) to
compensate for spring force, wind conditions, etc.
Obst Delay:
0 - 5 sec in 1 sec increments
3s
Obstruction Delay: the amount of time the operator will push against an
obstruction before closing if during an opening cycle or reopening and trying to
close again if during a clocking cycle.