D6021/D6031 Double Unit Series

 (Push Side) Power Operator

433MHz Receiver User’s Guide

NOTE:

• 

Always stop pedestrian traffic through doorway when 

performing tests that may result in unexpected reactions 

by door.

• 

Ensure compliance with all applicable safety standards 

upon completion of installation.

• 

See diagrams on page 22 for wire colors.

Hand-Held Configuration

1.  Set dip switches to receiver to desired activation cycle (dip 

switch 1 - Toggle or Pulse and dip switch 2 - 0.5s or 10s hold.

2. 

Press either Learn w/ Delay Button or Learn w/o Delay 

Button on receiver depending on activation requirements 

(if delay learn is selected, adjust potentiometer to 

counterclockwise limit, 0 second delay). Red LED on 

receiver will flash. After learn cycle is complete, adjust 

potentiometer to desired delay time (0 - 30 sec).

3.  Depress transmitter button repeatedly until Blue LED on 

receiver illuminates (indicating reception of signal from 

transmitter). 

NOTE: Repeat Steps 2 - 3 to program additional 

transmitters.

4.  To test system, depress transmitter button (Red LED on 

Transmitter will illuminate) and observe that Blue LED 

illuminates on receiver. This indicates that relay has been 

activated.

Push Plate Configuration

1.  Before beginning, prepare installation of push plate.

2.  Connect wires from transmitter to NO and COM contacts of 

push plate’s switch.

3. 

Follow Steps 1 - 4 (Hand-Held Configuration); depress push 

plate to activate transmitter.

4.  Attach transmitter to inside of electrical box and complete 

installation.

Removing Transmitter Code(s)

Single Transmitter Code:

•  Press both Delay and No Delay Buttons simultaneously until 

Red LED flashes once (approximately 1 second).

•  Press transmitter button twice within 10 seconds and 

transmitter code will be deleted.

All Transmitter Codes:

•  Press and hold both Delay and No Delay Buttons 

simultaneously until Blue LED illuminates then release 

(approximately 10 seconds).

Red LED

Blue LED

Antenna Wire

Learn
w/o Delay
Button

Delay
Potentiometer
(Time Adjustment)

Learn w/
Delay Button

DIP Switch

Terminal
Strip

Troubleshooting

Problem

Solution

LED on receiver is flickering - unable to 

program and/or won’t work

Push plate stuck or faulty transmitter. Disconnect each push plate until LED goes 

out. If LED does not go out, remove each transmitter battery until it does. Replace 

appropriate

 

transmitter.

Receiver intermittently doesn’t receive 

transmitter(s) signal.

Extend receiver antenna wire only in multiples of 6-3/4" (171)

 

Example: 6.75 x 4 = 27" (686) of extended antenna wire.

ON

1    2

PUL

TO

G

0.5s     10s

ON

1    2

PUL

TO

G

0.5s     10s

In Toggle Setting (1-ON),  Hold

Time is inactive. Either setting

for #2 dip switch will have

same result.

ON

1    2

PUL

TO

G

0.5s     10s

0.5 second

Pulse Setting

ON

1    2

PUL

TO

G

0.5s     10s

10 second

Pulse Setting

#1

Description

Function

OFF

Pulse Relay

Press transmitter once and relay will be active momentarily.

ON

Toggle Relay

Press transmitter once and relay output is active indefinitely. 

Press it again and relay will de-energize indefinitely.

#2

Description

Function

OFF

0.5s Hold Time Relay will remain active 0.5 sec after loss of activation.

ON

10s Hold Time Relay will remain active 10 sec after loss of activation.

Summary of Contents for Norton D6001BP-38-LH

Page 1: ...nverter 6000IN End Cap LH 6001ENLH Union Spacer 6001US Operator LAP 6021LAP Inverter 6000IN Power Supply 6000SUP Power Module Sub assembly 6001PM Closer Assembly 7500LAP Main Arm and Rod 6030 1W Adjus...

Page 2: ...cal Data 4 Prepare Frame and Doors 5 Install Operators 8 Install Track and Arm 11 Adjustments 12 Power Operators 13 Sync Operators 14 Finalize Installation 15 General Electrical Information 15 Wiring...

Page 3: ...thers required Closing When the hold open time has elapsed the door closer will close the door automatically The door will slow to low speed at latch before it reaches the fully closed position The do...

Page 4: ...ased on 1 8 gap between door and frame All dimensions are given in inches DO NOT scale drawings Thickness recommended for reinforcements in hollow metal doors and frames is charted This template infor...

Page 5: ...r shimming is required Failure to mount units properly can result in improper function of operator or inability to snap on covers 3 Mark center of opening on frame header between jambs 4 Using chart m...

Page 6: ...ing backplate as template mark conduit slot and Dim D mounting hole Figure 5 NOTE Dim D should be 5 16 up from bottom of frame header if backplate is properly aligned 7 Drill hole for mounting screw a...

Page 7: ...t to properly secure top edge of backplate Use of blocking supplied by others or shims provided to fill gap between backplate and wall above header is HIGHLY recommended Material must comply with loca...

Page 8: ...LAP so spring tube of closer is pointed toward closest hinge edge of frame Slide each LAP over two 2 screws and tighten Figure 11 NOTE When properly oriented spring tube is at bottom on left hand bac...

Page 9: ...embly so two 2 conduit holes are at bottom and text on wire input label is legible Figure 13 2 Secure assembly to backplate using four 4 8 32 x 5 16 Phillips head screws Figure 13 WARNING BUILDING POW...

Page 10: ...or Operator LAP 10 Pin Black Connector Operator LAP 3 Pin White Connector Power Module Sub assembly 3 Pin White Connector Power Module Sub assembly 10 Pin Black Connector Operator LAP 10 Pin Black Con...

Page 11: ...l two 2 1 4 20 x 1 5 8 screws through each shoe and into sex bolts Figure 19 NOTE Orient shoe with short side of shoe toward hinge Figure 20 View from ceiling looking downward Short Side of Shoe Hinge...

Page 12: ...reach nut remove Torx screw in end cap access door and slide door open When finished slide access door closed and reinsert 6 Torx flat head screw to secure door Figure 26 Adjustments A Adjust mechani...

Page 13: ...sh up or down on joystick Figure 27 To change setting of a menu item when cursor is on that item push joystick left right to increase decrease value NOTE Values will auto save 3 seconds after adjustme...

Page 14: ...o Single increase to Dbl Follower NOTE Dbl MasterCoord to be used when astragal or similar is attached to Master door or as a replacement for a mechanical door coordinator Once set Master Figure 29 Un...

Page 15: ...backplate verify backplate is not warped or twisted Additional support or shimming may be required See Sections A B under Prepare Frame and Door WARNING Make sure no wiring is loose or can be caught b...

Page 16: ...ce connected to Aux 1 is sending constant signal Aux 2 Stuck Activation device connected to Aux 2 is sending constant signal Aux 3 Stuck Activation device connected to Aux 3 is sending constant signal...

Page 17: ...mware Rev Single Single Door Dble Follow Dble Master Dble Mast Coord Single Set on Single for a single stand alone door Dble Follow for Follower door on pair of doors Dble Master for Master door on a...

Page 18: ...Function with Switches For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed Fail Secure Electric Strike 24VDC Wiring For Master Follow...

Page 19: ...to NC For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed and latched Activating switch will energize exit device and door will automa...

Page 20: ...osed Activating switch will open door Door will remain in indefinite hold open until activating switch is activated a second time causing door to close Change Factory Pre Wiring to Illustration Below...

Page 21: ...t be used to connect inverters Doors are normally closed and latched Fire Alarm activation will retract exit device latch bolt and door operator will open door Door will remain open until the Fire Ala...

Page 22: ...ed Activating wireless switch or hand held wireless transmitter will open door Door will remain in indefinite hold open until wireless switch or hand held transmitter is activated a second time causin...

Page 23: ...re normally closed and latched Activating outside door switch will open outside door After vestibule time delay has elapsed a signal will be sent to inside door which will open Activating inside door...

Page 24: ...eps 1 4 Hand Held Configuration depress push plate to activate transmitter 4 Attach transmitter to inside of electrical box and complete installation Removing Transmitter Code s Single Transmitter Cod...

Page 25: ...will close after hold open time delay has elapsed If door is closed and 585 Presence Detector senses something in opening door will not open If door is at open position and 585 Presence Detector sens...

Page 26: ...oller screen If DT is set to Standard this is normal Door Toggle mode and will not work with Presence Sensor set to Stall door closing will stall until presence not sensed set to Return Open presence...

Page 27: ...ing When door reaches open position door drifts further open Decrease Hold Speed on controller see page 17 until door stops drifting When door reaches open position door bounces Decrease Slow Speed on...

Page 28: ...d Reproduction in whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group Inc is prohibited 80 9360 1030 020 Rev 6 11 20 D 2 7 60 1 reveal 6 8 175 max...