D6021/D6031 Double Unit Series
(Push Side) Power Operator
Double Door Radio Frequency Standard Function Wiring
Double Door Radio Frequency Executive Function Wiring
•
For Master/Follow or
Master-Coord/Follow only
(Sync Cable must be used
to connect inverters.)Doors
are normally closed and
latched.
• Activating wireless switch
or hand held wireless
transmitter will open door.
• Door will remain in
indefinite hold open until
wireless switch or hand held
transmitter is activated a
second time causing door
to close.
• Current draw at Power
Outputs not to exceed 1.3
amps.
If Installing in the Field, change Factory Pre-Wiring to Illustration Below (move NO to +24)
If Installing in the Field, change Factory Pre-Wiring to Illustration Below (move NO to +24)
•
For Master/Follow or
Master-Coord/Follow only
(Sync Cable must be used to
connect inverters.)
• Doors are normally closed.
• Activating wireless switch
or hand held wireless
transmitter will open door.
• Door will close after hold
open time delay has
elapsed.
• Current draw at Power
Outputs not to exceed 1.3
amps.