• Switches are mounted so that the user is in
full sight of the door when activating the
switch.
2. Unless otherwise approved by the Authority Having
Jurisdiction (AHJ), CONSULT ANSI A117.1,
“Standard on Accessible and Usable Buildings and
Facilities,” and other applicable building codes for
additional information regarding accessibility
requirements for the door and the area around the
door.
• Switches are not located in a position where
the user would be in the path of the moving
door.
NOTE:
The instructions for installing the pushbutton
switches, installing the plug-in transformer, adjusting
door spring tension, and replacing the battery pack
fuse are common regardless of whether the door is a
push or pull application.
• Switches remain accessible from the swing
side when the door is opened.
• Switches are mounted at a minimum height of
34
″
(86 cm) and a maximum height of 48
″
(122 cm).
1. Refer to Figure 27, and INSTALL the pushbutton
switches. ENSURE the following:
• Switches are located 1' to 12' (30 cm to 3.7m)
from the door.
Miscellaneous Common Insructions
8
700002-Rev N 09/18
®
5800 ADAEZ PRO
Installation and Operation Instructions
29 of 50
Installing the Pushbutton Switches
Figure 27