Pool Chemicals
Connection
Screw the
injection valves
into the plug D = 50 with thread G1 / 4 “# 12134,
glued to the T-piece.
Tighten by hand only. Do not use pliers or other
tools.
Connect the
FLOC+C INJECTION VALVE
to the pipe before the coagulation
mixer and before the filter.
Connect the
ALGICIDE, pH, and CHLOR PURE INJECTION VALVE
to the
pipe behind the filter and behind the drainage of the measured water. Con-
nect injection valves in this order to prevent scale formation.
To connect reagents from cans to the ASIN AQUA and from the ASIN AQUA
to the injection valve use PE Tube 1/4 “(6.35 mm) # 12008, which is part of
the delivery.
CANISTER CONNECTION
Drill 6.35 mm and 1 mm diameter holes in the
canister cap. Pass the pipe through the cap so that it reaches to the bottom
of the canister. Place the suction basket at the end of the pipe.
PUMP CONNECTION
connect the suction of the pump on the left to the
canister connect the pump discharge on the right to the injection valve.
INJECTION VALVE CONNECTION
Pass the pipe through the nut, thread
the pipe onto the injection valve and tighten the nut firmly by hand.
1
2
3
4
5
WARNING
To ensure that the joints are tight, cut the PE tube at an angle of 90 °. Use spe-
cial pliers # 13325 to cut plastic tubes. The cut must be clean and smooth. Do
not use ordinary scissors or knives!
WARNING
NEVER CONNECT pH minus reagent to disinfection pump or disinfectant
to pH pump!
In the case of a cross-connection, after ten doses ASIN AQUA
displays an error message. Repair the piping installation and then you can
continue to operate your ASIN AQUA.
CHLORINE
pH
ALGICID
FLOCC
TO POOL
FROM SKIMMER
FROM BOTTOM
Max 8 m
CHL
OR PURE
pH MINUS
AL
GICID
FLOC+C
M
ax 8 m
M
ax 2 m
Ø 1 m
m
Ø 6
,3
5 m
m
5
4
3
Plug with
D = 50 with
thread 1/4“
T-joint