EN
8
max 8 m
CHLORINE
pH
ALGICID
FLOCC
40 °C
m
ax
.
5 °C
m
in
.
40 cm
40cm
40 cm
40 cm
150 cm
18,5 cm
18,5 cm
CHLORINE
pH
ALGICID
FLOCC
m
ax
2 m
CHLORINE
pH
ALGICID
FLOCC
Wall bracket
ASIN AQUA Home Installation
ASIN AQUA Home is to be wall-mounted in a dry and dust-free environment
with temperatures ranging from +5 °C to +40 °C.
Install the mounting rail to attach ASIN AQUA Home to the wall. Choose the
location so that there is a free space of at least 40 cm in all directions and
the height above the floor is not higher than 150 cm. Drill three holes in the
wall at a distance of 18.5 cm. Use screws supplied with ASIN AQUA Home for
attachment.
RECOMMENDATION:
ASIN AQUA Home must be installed in a way that in the event of a chemical
leak from the pumps or tubes, the equipment will not be damaged or chemi-
cals will not spill onto the floor. Use drip trays.
Do not install any other devices under ASIN AQUA Home.
WARNING:
The location temperature should permanently be in the range
from +5 °C to +40 °C.
Direct sunlight, high humidity and dust may lead to damage to
ASIN AQUA Home.
•
Before installing, ensure that pool water is chemically clean and free
of dirt.
•
The maximum distance of injection valves from peristaltic pumps of
ASIN AQUA Home must not be greater than 8 m.
•
Vertical distance between ASIN AQUA Home and the bottom of
containers must not exceed 2 m.
Summary of Contents for ASIN AQUA Home VS
Page 42: ...CS 42...
Page 43: ...CS 43...
Page 44: ...www asekopool com ASIN AQUA Home VS USER MANUAL EN...