Configuration
Date and Time
To ensure the correct function of timers, set the current date and time.
Pool Volume
To ensure the correct function of ASIN AQUA Home, enter the correct
volume of your. Calculate your pool volume in m
3
:
Length (L) times width (W) times depth (D) is volume (V) - (L × W × D = V).
Enter the value using + and - buttons.
WARNING:
The pool volume has effect on the maximum safe dose, enter
the correct value.
Filtration Timer
Filtration can be set to NONSTOP operation for 24 hours or to one, maximum
to two time periods.
Variable Pump Control
ASIN AQUA Home allows to control the SPECK or PENTAIR variable output
circulating pumps. The pump runs at speed 2 in filtering periods, besides
the preset filtering (when the standard pump is off) it runs at speed 1 (or
can stay switched off according to your choice). In case of backwashing, the
pump is running at speed 3.
Individual speeds 1, 2, 3 are adjusted directly on the pump according to the
respective pump manual.
Automatic Filter Washing
Considering that the ASIN AQUA Home technology is in particular based
on the high efficiency of filtering and removing even the finest impurities,
it is necessary to
wash the filter on a regular basis.
The automatic
washing function ensures the filter washing on a regular basis in the
preselected intervals.
To enable this function, it is necessary to use the automatic 5-way
BESGO valve.
Its moving is enabled by the relay switching on. When the relay
switches on, the BESGO valve is enabled and moved to the required position
by the action of pressure water or air. See the BESGO manual.