6.4.2 Systems Equipped With The Seamless Transfer Option
The generator must be started and be prepared to accept the ship’s electrical loads.
Measure the generator voltage using the converter’s metering display, selecting the GENERATOR
POWER (3) function. The voltage and frequency must be the same as the converter’s output in order
for the seamless transfer option to successfully transfer power. The SHORE POWER LED (7A)
must be lit at this time.
When the generator is ready to accept the ship’s loads, press the
SHIP’S POWER - GENERATOR
button (12). In dual-generator installations, a display will appear requesting that the appropriate
generator be selected via the
F1
and
F2
(13) buttons. In single-generator installations, the transfer
will proceed. The converter will match the generator in frequency, voltage, and phase over a several
second period. When the power forms are matched, the converter will close the generator circuit
breaker, then open the converter output contactor, with both briefly operating in parallel. The
SHIP’S POWER - CONVERTER LED (9A) should now be off, and the SHIP’S POWER -
GENERATOR LED (12A) should now be lit.
With the ship’s loads now being serviced by the generator, the converter may be shut down. Press
the
CONVERTER POWER OFF
button (11). The red OFF LED (11A) should now be lit. The
converter is now in the standby state.
Next press the
SHORE POWER OFF
button (10). The red OFF LED (10A) should now be lit, and
the converter will begin an orderly shutdown. The complete shutdown process will take about 10
seconds. The converter power metering display, if observed during the process, will indicate a slow
decay in the output voltage to zero. Rotate the disconnect switch (14) to the OFF position. The
system is now off and power can be removed from the equipment.
Summary of Contents for AC100LC-3
Page 42: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 42 This page intentionally left blank ...
Page 62: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 62 11 MSDS SHEET COOLANT OIL ...
Page 63: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 63 11 MSDS SHEET COOLANT OIL cont ...
Page 64: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 64 11 MSDS SHEET COOLANT OIL cont ...
Page 65: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 65 11 MSDS SHEET COOLANT OIL cont ...
Page 66: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 66 11 MSDS SHEET COOLANT OIL cont ...
Page 67: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 67 11 MSDS SHEET COOLANT OIL cont ...
Page 68: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 68 11 MSDS SHEET COOLANT OIL cont ...