CALIBRATION
In an uncalibrated state the input and output voltage and input current metering system should be
within 3%. The uncalibrated output current meter is normally 5% low. For calibration an external
reference voltmeter will be required along with a calibrated current transformer or probe. If the
system is to be calibrated on board using the yacht’s loads, attempt to shut down all transient
(fluctuating) loads if possible. Cyclic loads will complicate the current meter calibration process.
This procedure must also be followed after replacing the battery on a maintenance basis
1)
Turn the system off and secure input power. Remove the front cover.
2)
Remove the lower front protective panel from the system, and set it aside. The input and
output power terminal blocks will be located at the bottom of the power panel located in the lower
compartment. Refer to the installation section of the Operations Manual for additional information.
Re-apply power to the system and bring the system on-line. Transfer the yacht’s load (or external
test load bank) to the converter.
3)
Shore Power Calibration
- Press the
SHORE POWER
(2) button under the LCD (1)
display. Use an external reference meter and current transformer or clamp to measure the input
(shore power) power at the input terminal block. To enter the meter calibration screen, press and
hold the
SHORE POWER
(2) button down for 7 seconds, or until the calibration display appears,
then release the button. Use the
SHORE POWER
(2) button to move the cursor to the parameter to
be calibrated, voltage or current. Change the selected parameter by pressing the
F1
button to
increment and the
F2
button to decrement the displayed value. When all displayed values equal the
values measured by the reference meter, pressing the
SYSTEM STATUS
(5) will store the new
calibration values and return the display to the System Status display. Press the
SHORE POWER
(2) button to verify proper shore power meter calibration.
Summary of Contents for AC100LC-3
Page 42: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 42 This page intentionally left blank ...
Page 62: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 62 11 MSDS SHEET COOLANT OIL ...
Page 63: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 63 11 MSDS SHEET COOLANT OIL cont ...
Page 64: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 64 11 MSDS SHEET COOLANT OIL cont ...
Page 65: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 65 11 MSDS SHEET COOLANT OIL cont ...
Page 66: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 66 11 MSDS SHEET COOLANT OIL cont ...
Page 67: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 67 11 MSDS SHEET COOLANT OIL cont ...
Page 68: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 68 11 MSDS SHEET COOLANT OIL cont ...