CONVERTER OUTPUT VOLTAGE CONTROL
Vout = XXX.X
More Less XXXV Exit
7.8
CONVERTER OUTPUT VOLTAGE CONTROL
Press the
CONVERTER POWER + F5
buttons to access the CONVERTER OUTPUT
VOLTAGE CONTROL display.
This function allows the user to increase or decrease the converter output voltage (Vout). Press the
More
(F1)
button to increase the Vout, the Less
(F2)
button to decrease the Vout, the XXXV
(F3)
button to return Vout to the factory programmed setting, and the Exit
(F5)
button to save the setting
and exit.
Default
Range
Increments
Vout
factory prog. voltage
+/-5%
0.5 volts
Application: if the line-drop losses in a yacht are such that locations remote of the converter and
Ship's Bus experience undesirable, lower-than-expected voltages, the programmed Vout can be
raised up to 5% via this function. Also, to decrease total power usage, the Vout could be reduced up
to 5%. The new, programmed Vout will be used as the basis for AGC, Seamless Transfer, and all
other voltage dependent functions.
Summary of Contents for AC100LC-3
Page 42: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 42 This page intentionally left blank ...
Page 62: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 62 11 MSDS SHEET COOLANT OIL ...
Page 63: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 63 11 MSDS SHEET COOLANT OIL cont ...
Page 64: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 64 11 MSDS SHEET COOLANT OIL cont ...
Page 65: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 65 11 MSDS SHEET COOLANT OIL cont ...
Page 66: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 66 11 MSDS SHEET COOLANT OIL cont ...
Page 67: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 67 11 MSDS SHEET COOLANT OIL cont ...
Page 68: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 68 11 MSDS SHEET COOLANT OIL cont ...