Ascotel® IntelliGate® 2025/2045/2065 as of I7.9
248
Operation and Maintenance
sy
d-
020
4/1.
7
– I7.
9
– 1
2
.2009
6. 5. 5. 3
Fault & Maintenance Manager
For information on the Fault & Maintenance Manager see
.
6. 5. 5. 4
System Event Manager SEM
For information on the System Event Manager (SEM) see
6. 5. 5. 5
Measuring equipment for cordless systems
The aids required for measuring out DECT systems are described in the “Ascotel
DECT System” System Manual.
6. 5. 6
Error causes and error handling
The following tables contain a systematic list of occasional errors. These tables are
designed to help you pinpoint and remedy errors more easily.
When the system is operating correctly, the decimal point on the mainboard's 7-
segment display flashes regularly.
In the event of sporadic errors check the installation for earth loops.
6. 5. 6. 1
Output of error codes in the PBX and on the Crystal
Whenever the system detects an error, it displays the corresponding error code on
the mainboard's 7-segment display (providing the system is still powered and the
display is working).
There are 2 types of error:
•
Unrecoverable errors that lead to a restart. The current system software is unable
to remedy the error that has occurred. The system is reset and the initialization
restarted.
•
Errors following the failure of partial functions. These errors occur when the user
carries out a function incorrectly or when non-critical system components fail.