Possible faults
52
Display
Designation
Reasons
Remedy
C1
Microswitch transport posi-
tion does not switch
Fuse no. 5 (10 A) has blown.
Eliminate cause of fuse trigger and replace
fuse.
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
Cutting height adjustment is blocked.
Remove blockage.
C2
Blade switches off after 5
seconds.
No activation of a control function in the
RC mode.
Engaging blade.
F1
Drive lever does not work
(RC)
Drive lever / rods blocked.
Remove blockage.
Selection lever operating mode is not
completely set to RC.
Flip the selection lever of the operating mode
all the way.
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
F2
Drive lever does not move
to middle position (RC)
Drive lever / rods blocked.
Remove blockage.
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
Selection lever operating mode is not
completely set to RC.
Flip the selection lever of the operating mode
all the way.
F3
Angle sensor driving
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
F4
Steering does not work
(RC)
Steering is blocked by the ground.
Steer in accordance with the ground proper-
ties.
Steering / rods blocked.
Remove blockage.
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
Selection lever operating mode is not
completely set to RC.
Flip the selection lever of the operating mode
all the way.
F5
Angle sensor steering
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
F6
Blade is not properly en-
gaged or disengaged
Fuse no. 5 (10 A) has blown.
Eliminate cause of fuse trigger and replace
fuse.
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
F7
Blade status unclear
Fuse no. 5 (10 A) has blown.
Eliminate cause of fuse trigger and replace
fuse.
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
F8
Engine status unclear
Engine status unclear, device is not safe
for operation.
Autorisierte Fachwerkstatt.
F9
Microschalter
Höchste Schnitthöhe schal-
tet nicht
Fuse no. 5 (10 A) has blown.
Eliminate cause of fuse trigger and replace
fuse.
Fuses nos. 1-3 (10 A) have blown.
Eliminate cause of fuse trigger and replace
fuse.
Cutting height adjustment is blocked.
Remove blockage.
FU
Interruption of radio trans-
mission
Battery on the Remote Control Transmit-
ter is empty.
Replace battery.
Battery on the device is empty.
Charge the battery (see Checking the bat-
tery) or have authorized service center do so.
Radio range exceeded.
Reduce distance between Remote Control
Transmitter and receiver.
Summary of Contents for AS 940 SHERPA 4WD RC