6. Specifications.

Conditions

parameters

Deviation

AC Power Supply

Voltage selector between  

115 V & 240 V

AC 115- 240 V; 50 / 60 Hz  

Specific voltage and frequency 

values to the machine to prevail 

in kind.

10 %

DC Power Supply

+ 24 V

± 4 V

Line Input Sensitivity

Clockwise rotation gain to increase

195 mV-2.0 V

Line Input Impedance

47 K Ω

Local Input Sensitivity

Balanced input

500 mV

Local Gain

± 8 dB

MIC1 Sensitivity

Clockwise rotation gain to increase

MIC1 Impedance

600 Ω

MIC Level Control

Input 100 Hz sine wave signal

± 8 dB

Paging Console Sensitivity

Input 1 KHz sine wave signal & output 

0.775 V

500mV

Paging Console Gain Control

± 8 dB

Zone Output

Balanced output

0.775 V

Zone Gain Control

± 8 dB

Zone Output Level Control

Input 100Hz sine wave signal

10 dB

S/N Ratio

Non-weighting

< 60 dB

Isolation Degree

> 40 dB

Channel Crosstalk

> 50 dB

Gain Deviation

20 Hz-20 KHz

< 2 dB

T.H.D

20 Hz-20 KHz

< 0.07%

Channel Phase Position

20 Hz-20 KHz

Same phase

Frequency Response

Line 1-8 inputs and remote source 

input, 20 Hz-20 KHz

+L / -3 dB

Frequency Response

MIC1 input, 80 Hz-18 KHz

+L / -3 dB

Summary of Contents for MAT-8000

Page 1: ...to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference Check our website for any updates of this manual www artsound be House of Music NV R...

Page 2: ...TABLE OF CONTENTS 1 Safety precautions 3 2 Introduction 5 3 Front panel layout 5 4 Rear panel layout 7 5 rs 485 communication protocol 10 6 Specifications 12 7 Connection diagram 13 8 Connection and...

Page 3: ...Using a voltage higher than that which is specified may result in fire or electric shock Do not cut kink otherwise damage nor modify the power supply cord In addition avoid using the power cord in clo...

Page 4: ...f the unit falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc If it is malfunctioning no tone sounds To prevent a fire or electric shock never ope...

Page 5: ...rol panels the zone source select button will be disabled when a remote control panel is connected to a zone In this situation the source selection can only be controlled via the remote control panel...

Page 6: ...n sequence as follows 1 2 3 4 5 6 7 8 and OFF A zone can be selected pressing the ZONE SELECT button Once the display shows the desired zone press the ENTER button to confirm and change to the selecte...

Page 7: ...VE3 SLAVE4 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 Extension Matrix 3 Extension Matrix 1 Master Matrix Extension Matrix 2 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 dB GAIN HF LF...

Page 8: ...set at 300 mV 1 1 v 10 K Ohm 7 Remote Control Panel Input Each of the eight zones can have a remote control panel connected The Remote control Panel will enable the source and volume to be controlled...

Page 9: ...s detected the EMC Input will be open and take priority over all other inputs The EMC Input will only take priority and broadcast to zones where there is a Zone Fire Alarm Dry Contact Closure Each zon...

Page 10: ...in at 100hz 10dB RS 485 Communication Protocol Baud Rate 57600 bps S Parity Check Odd parity check Data 16 bytes Accumulation 2nd data byte 3rd data byte 4th data byte MAT 8000 Inquiry Data The MAT 80...

Page 11: ...one The inquiry command which is from the Matrix to the remote wall plate is both inquiry and status data to update the wall plate status ie source input zone volume The inquiry data format is hA 20 l...

Page 12: ...n gain to increase MIC1 Impedance 600 MIC Level Control Input 100 Hz sine wave signal 8 dB Paging Console Sensitivity Input 1 KHz sine wave signal output 0 775 V 500mV Paging Console Gain Control 8 dB...

Page 13: ...0 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1...

Page 14: ...nsion Keypad Dip Switch Setting There are 4 address codes on both remote the paging console and the extension keypad which are used to identify these Please Note Only one address code switch of each d...

Page 15: ......

Page 16: ...Discover the complete ArtSound range at www artsound be TM Art_Sound House Of Music SA NV Ronse Belgium www artsound be Tel 32 9 380 81 80 Fax 32 9 386 12 35 info artsound be...

Reviews: