background image

MAT-8000

10

19. pAgINg MIC gAIN
The Paging MIC Gain control will adjust the Paging 

MIC Input Signal Level. Each Paging MIC will have its 

own gain control.There by each Paging MIC can be set 

 independently of the other Paging MICs.

20. MIC1 INpUT
The balanced MIC1 input XLR type has an impedance of 

600ohms. Each zone has a MIC1

Priority Button. When the MIC1 priority button is not 

enabled,MIC1 will be mixed with the line inputs on 

each zone (1-8 or L). When the MIC1 priority button is 

enabled,MIC1 will take priority over all line inputs (1 - 8 

or L) as well the wall control panel for that zone.

MIC1 will have priority only on Zones where the MIC1 

Priority Switch is enabled on the front panel.

Zones where the MIC1 priority switch is not enabled, 

MIC1 will mix with the Source Selected for the Zone.

The MIC1 level will be controlled by the MIC1 Level 

 Adjustment Knob and the Master Level Adjustment Knob.

The MIC1 signal will be sent to any extension Matrix 

 connected to the system.

21. MIC1 gAIN
The MIC1 Gain controls the MIC1 range from 5 mV to 

300 mV.

22. MIC1 BASS
The MIC1 Bass controls the MIC1 gain at 100hz  

(+/-10dB).

RS 485 Communication protocol
Baud Rate: 57600 bps / S Parity

Check: Odd parity check

Data: 16 bytes

Accumulation = 2

nd

 data byte

+3

rd

 data byte + 4

th

 data byte

MAT-8000 Inquiry Data
The MAT-8000 sends inquiry data to 2 remote paging 

consoles, 8 remote wall panels and extension Matrix. 

The new data will feedback to the Matrix when any new 

data has been checked. Any extension MAT-8000 will only 

enquire to its own 8 remote wall panels only.

Inquiry Data To paging Console
The MAT-8000 sends the inquiry data to remote paging 

consoles in the following format:

AA 10 00 00 AM (accumulation)

AA: data head

10: inquiry to the paging console

00: meaningless

AM: (accumulation = 2nd data byte

+ 3

rd

 data byte + 4

th

 data byte)

Feedback Data From paging Console
The feedback data from the remote paging console to the 

Matrix after got inquiry and ready for paging

format as:

AA 11 Matrix address code zone data AM

AA: data head

11 : zone paging command

Matrix address code:

01 : master matrix,

02 : extension matrix 1

03 : extension matrix 2

04 : extension matrix

3 zone data: the zone data is in 8 bytes

0 : no paging

1 : paging, ie: binary system

00000011 B : zone 1 and zone 2 paging

00000100B : zone 3 paging

11111111 B : all 8 zone paging

AM: (accumulation = 2nd data byte

+ 3

rd

 data byte + 4

th

 data byte)

5. RS 485 communication protocol.

Summary of Contents for MAT-8000

Page 1: ...to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference Check our website for any updates of this manual www artsound be House of Music NV R...

Page 2: ...TABLE OF CONTENTS 1 Safety precautions 3 2 Introduction 5 3 Front panel layout 5 4 Rear panel layout 7 5 rs 485 communication protocol 10 6 Specifications 12 7 Connection diagram 13 8 Connection and...

Page 3: ...Using a voltage higher than that which is specified may result in fire or electric shock Do not cut kink otherwise damage nor modify the power supply cord In addition avoid using the power cord in clo...

Page 4: ...f the unit falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc If it is malfunctioning no tone sounds To prevent a fire or electric shock never ope...

Page 5: ...rol panels the zone source select button will be disabled when a remote control panel is connected to a zone In this situation the source selection can only be controlled via the remote control panel...

Page 6: ...n sequence as follows 1 2 3 4 5 6 7 8 and OFF A zone can be selected pressing the ZONE SELECT button Once the display shows the desired zone press the ENTER button to confirm and change to the selecte...

Page 7: ...VE3 SLAVE4 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 Extension Matrix 3 Extension Matrix 1 Master Matrix Extension Matrix 2 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 dB GAIN HF LF...

Page 8: ...set at 300 mV 1 1 v 10 K Ohm 7 Remote Control Panel Input Each of the eight zones can have a remote control panel connected The Remote control Panel will enable the source and volume to be controlled...

Page 9: ...s detected the EMC Input will be open and take priority over all other inputs The EMC Input will only take priority and broadcast to zones where there is a Zone Fire Alarm Dry Contact Closure Each zon...

Page 10: ...in at 100hz 10dB RS 485 Communication Protocol Baud Rate 57600 bps S Parity Check Odd parity check Data 16 bytes Accumulation 2nd data byte 3rd data byte 4th data byte MAT 8000 Inquiry Data The MAT 80...

Page 11: ...one The inquiry command which is from the Matrix to the remote wall plate is both inquiry and status data to update the wall plate status ie source input zone volume The inquiry data format is hA 20 l...

Page 12: ...n gain to increase MIC1 Impedance 600 MIC Level Control Input 100 Hz sine wave signal 8 dB Paging Console Sensitivity Input 1 KHz sine wave signal output 0 775 V 500mV Paging Console Gain Control 8 dB...

Page 13: ...0 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1...

Page 14: ...nsion Keypad Dip Switch Setting There are 4 address codes on both remote the paging console and the extension keypad which are used to identify these Please Note Only one address code switch of each d...

Page 15: ......

Page 16: ...Discover the complete ArtSound range at www artsound be TM Art_Sound House Of Music SA NV Ronse Belgium www artsound be Tel 32 9 380 81 80 Fax 32 9 386 12 35 info artsound be...