background image

Shades requires a -12V / +12V power supply (2x5 pin connector). The ribbon cable connector must be
aligned so that the red stripe of the ribbon cable (-12V) is on the same side of the module’s power header
as the “Red stripe” marking on the board. The module draws 15mA from both the +12V and -12V supply
rails.

This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.

This device meets the requirements of the following standards: EN55032, EN55103-2,
EN61000-3-2, EN61000-3-3, EN62311.

Each of the 3 channels of Shades can act as an attenuator or attenuverter.

A. Function selector

 This control selects configures the channel as an attenuator (lower position) or as

an attenuverter (upper position).

Mutable Instruments | Shades

1 of 3

Reviews: