11. gAIN
The Zone Gain control will set the 

maximum Source Output Volume Level 

for the Zone. 

This will ensure the user cannot adjust 

the Audio Level too high using the Master, MIC1 and 

 Music Level Control Knobs on the Front Panel. Gain will 

set the Maximum Output Volume of Line Source and 

MIC1. It will have no control over the Paging Level.

12. hF 
The Zone HF Treble of the Zone Output 

can be controlled by adjusting the  

HF Treble Level Control. 

This Level Control will provide adjust-

ment of the 100Hz AudioFrequency by 

10 dB.

Every Zone has a HF Treble Level Control which enables 

the HF Treble Level of each zone to be set independently 

of other zones.

13. ENABLE/DISABLE SWITCh
If a Zone Remote Wall Control Panel is 

to be used with the System, the RJ45 

Remote Control Panel Input needs to 

be enabled. The RJ45 Remote Control 

Panel Input is enabled/disabled by 

pressing the Enable / Disable Switch. 

Every Zone has an RJ45 Remote Con-

trol Panel Input  Enable / Disable Switch.

NOTE: Only Enable when a Zone Remote Wall Control 

Panel is connected.

14. REMOTE SOURCE gAIN
The Zone Local Source Input Signal 

Level can be adjusted from 190 mV to 

200 mV using the Remote Source Gain 

control. This will enable the signal 

level of all sources to be equalized 

there by ensuring Output Volume Level 

remains constant when switching from 

one source to another source. Every Zone Remote Source 

Input has a Gain Control.

15. FIRE ALARM
There are Fire Alarm dry contacts for zones 1-8. When 

Dry Contact is detected the EMC Input will be open and 

take priority over all other inputs.

The EMC Input will only take priority and broadcast to 

zones where there is a Zone Fire Alarm Dry Contact 

 Closure.Each zone has a separate Fire Alarm Dry  Contact. 

Fire alarm, alert, EVAC and EMC in are of equivalent 

priority.

16. LINE gAIN
The System Line Source Input Signal Levels can be 

adjusted from 190mV to 200mV using the Line Source 

Input Gain control. This will enable the signal level of all 

sources to be equalized there by ensuring Output Volume 

Level remains constant when switching from one source 

to another source.

All system source inputs L(lines 1-8) have a separate 

Gain Control.

17. LINE INpUTS
The system has 4 Line Inputs, as well as 4 inputs 

 selectable as mic or line with phantom power available.

Every Line Source Input has a dual RCA Phono Connector, 

which will enable a Stereo Source Signal to be connected. 

Note, however, this is a Mono system and a Stereo Input 

will be combined to give a Mono Output. 

The Line Inputs have an impedance of 47 K Ohms

1. Line 1-8 source inputs will be selectable using the 

Source Select control on the front of the Matrix.

2. The selected source input number will be indicated on 

the Matrix zone display.

3. Any extension Matrix unit connected to the system will 

use sources line 1-8 from the master Matrix.

4. Only one set of input sources for lines 1-8 can be 

 connected per system.

18. pAgINg CONSOLE INpUTS
Up to two paging consoles can be con-

nected to the system simultaneously via 

the two paging console RJ45 input ports.

The paging consoles will have equal pri-

ority and will operate on a first come first 

served basis. The RJ45 pin assignment 

order is as below:

Summary of Contents for MAT-8000

Page 1: ...to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference Check our website for any updates of this manual www artsound be House of Music NV R...

Page 2: ...TABLE OF CONTENTS 1 Safety precautions 3 2 Introduction 5 3 Front panel layout 5 4 Rear panel layout 7 5 rs 485 communication protocol 10 6 Specifications 12 7 Connection diagram 13 8 Connection and...

Page 3: ...Using a voltage higher than that which is specified may result in fire or electric shock Do not cut kink otherwise damage nor modify the power supply cord In addition avoid using the power cord in clo...

Page 4: ...f the unit falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc If it is malfunctioning no tone sounds To prevent a fire or electric shock never ope...

Page 5: ...rol panels the zone source select button will be disabled when a remote control panel is connected to a zone In this situation the source selection can only be controlled via the remote control panel...

Page 6: ...n sequence as follows 1 2 3 4 5 6 7 8 and OFF A zone can be selected pressing the ZONE SELECT button Once the display shows the desired zone press the ENTER button to confirm and change to the selecte...

Page 7: ...VE3 SLAVE4 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 Extension Matrix 3 Extension Matrix 1 Master Matrix Extension Matrix 2 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 MASTER SLAVE1 SLAVE2 SLAVE3 SLAVE4 dB GAIN HF LF...

Page 8: ...set at 300 mV 1 1 v 10 K Ohm 7 Remote Control Panel Input Each of the eight zones can have a remote control panel connected The Remote control Panel will enable the source and volume to be controlled...

Page 9: ...s detected the EMC Input will be open and take priority over all other inputs The EMC Input will only take priority and broadcast to zones where there is a Zone Fire Alarm Dry Contact Closure Each zon...

Page 10: ...in at 100hz 10dB RS 485 Communication Protocol Baud Rate 57600 bps S Parity Check Odd parity check Data 16 bytes Accumulation 2nd data byte 3rd data byte 4th data byte MAT 8000 Inquiry Data The MAT 80...

Page 11: ...one The inquiry command which is from the Matrix to the remote wall plate is both inquiry and status data to update the wall plate status ie source input zone volume The inquiry data format is hA 20 l...

Page 12: ...n gain to increase MIC1 Impedance 600 MIC Level Control Input 100 Hz sine wave signal 8 dB Paging Console Sensitivity Input 1 KHz sine wave signal output 0 775 V 500mV Paging Console Gain Control 8 dB...

Page 13: ...0 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1 6 7 8 10 9 2 3 4 5 0 1...

Page 14: ...nsion Keypad Dip Switch Setting There are 4 address codes on both remote the paging console and the extension keypad which are used to identify these Please Note Only one address code switch of each d...

Page 15: ......

Page 16: ...Discover the complete ArtSound range at www artsound be TM Art_Sound House Of Music SA NV Ronse Belgium www artsound be Tel 32 9 380 81 80 Fax 32 9 386 12 35 info artsound be...

Reviews: