Hardware Preparation and Installation
SharpSwitch™ PCIE-9205 Installation and Use (6806800U18D)
37
The following table provides the environmental and the thermal requirements for the PCIE-
9205 card.
2.2.2
Power Requirements
The following table provides the typical power consumed by the PCIE-9205 card.
Table 2-1 Environmental and Thermal Requirements
Requirement
Operating
Non-Operating
Temperature
0°C to 35°C
-40°C to 70°C
Minimum Airflow
(Reference to sea level)
500 LFM (2.5 m/sec)
400 LFM (2 m/sec) for 35°C
Operation
-
Temperature Change
30°C/hr
30°C/hr
Relative Humidity
5% to 85% Non-Condensing
5% to 90% Non-Condensing but not to
exceed 0.024 kg of water per kg of dry
air
Shock and Vibration
0.1G’s 5 to 200Hz
EN 300 019-2-2 Class 2.3
Altitude
Up to 1800m
With 40°C operation between
1800m and 4000m
Up to 12000m
Table 2-2 Power Requirements
Mode
PCIe slot power with expansion connector
Idle
60W (+/- 10%)
Active
100W (+/- 10%)
Peak
139W (+/- 10%)
Idle
: Power consumption of card with active CAUI interfaces.
Active
: Typical load.
Peak
: Maximum load (Estimated).
Summary of Contents for SharpSwitch PCIE-9205
Page 1: ...SharpSwitch PCIE 9205 Installation and Use P N 6806800U18D March 2018 ...
Page 6: ...SharpSwitch PCIE 9205 Installation and Use 6806800U18D 6 Contents ...
Page 8: ...SharpSwitch PCIE 9205 Installation and Use 6806800U18D 8 List of Tables ...
Page 10: ...SharpSwitch PCIE 9205 Installation and Use 6806800U18D 10 List of Figures ...
Page 22: ...SharpSwitch PCIE 9205 Installation and Use 6806800U18D Safety Notes 22 ...
Page 30: ...SharpSwitch PCIE 9205 Installation and Use 6806800U18D Sicherheitshinweise 30 ...
Page 62: ...Controls Indicators and Connectors SharpSwitch PCIE 9205 Installation and Use 6806800U18D 62 ...
Page 68: ...Functional Description SharpSwitch PCIE 9205 Installation and Use 6806800U18D 68 ...
Page 86: ...BIOS SharpSwitch PCIE 9205 Installation and Use 6806800U18D 86 ...
Page 101: ......