![ARRI arrilux 400 lighthouse Operating Instructions Manual Download Page 71](http://html.mh-extra.com/html/arri/arrilux-400-lighthouse/arrilux-400-lighthouse_operating-instructions-manual_2975793071.webp)
Technical Data of Lampheads
71
Technical Data of Lampheads
Technical Data
PAR
LITE
Lighthouse
Maximum temperature of housing
t
o
= 160 °C (320 °F)
t
o
= 200 °C (390 °F)
Maximum ambient temperature
t
a
= 45 °C (113 °F)
Minimum distance
(not front of lens) to
flammable objects
B
0.5 m (20")
Minimum distance
to areas illuminated
A
3.0 m (10 ft.)
3.0 m (10 ft.)
Operation angle (tilt)
± 90°
Protection class
I (grounded)
Protection rate according to
EN 60 529/IEC 29
IP20/IP23 (see page 15)
Nominal lamp power
400 W
Suitable lamps e.g.
Philips MSR 400 HR
Osram HMI 400 W/SE
Sylvania BA 400 SE HR
Suitable ballasts
ARRI EB 400/575
ARRI EBB 200/400
Weight (without ballast
and accessories)
2.4 kg (5½ lb.)
2.5 kg (5¾ lb.)
cNTRL (UL) Listing
from serial number 760
CB / GS Certificate
from serial number 760
Compliant with the
following standards
EN 55015 (= CISPR 15)
EN 60598-1 (= IEC 60598-1)
EN 60598-2-17 (= IEC 598-2-17)
EN 61547 (= IEC 61547)
I
Caution!
Never use ballasts different from the ones specified by ARRI.
Due to different wiring of connectors, safety functions of the
ARRILUX 400 may be destroyed immediately!
Technical
Data
Summary of Contents for arrilux 400 lighthouse
Page 6: ...Übersicht 6 Übersicht 1 9 8 7 6 5 4 3 2 13 17 16 15 14 10 12 11 18 6 6 DAS PRODUKT ...
Page 72: ...Technische Daten Scheinwerfer 72 Abmessungen Technische Daten PAR LITE A 30 9 B 294 300 ...
Page 73: ...Technical Data of Lampheads 73 Dimensions Technical Data ...
Page 79: ...79 APPENDIX Bild Picture 50 Bild Picture 51 ...
Page 91: ...TÜV GS Zertifikat TÜV GS Certificate 91 APPENDIX TÜV GS Zertifikat TÜV GS Certificate ...
Page 93: ...CB Test Zertifikat CB Test Certificate 93 CB Test Zertifikat CB Test Certificate APPENDIX ...