Inserting Lamp – Relamping
33
I
Caution
: Nominal
ballast power must
match nominal lamp
power.
6
Take lamp by its
base (do not touch lamp
glass with bare hands)
and carefully insert it
into lamp holder (see
picture 10).
7
Slide lamp-holder
lock home (see pic-
ture 11).
I
Caution: Risk of
reflector breakage!
If lamp-holder lock
is not engaged, it
will not be possible
to insert lamphouse
into front housing.
I
Caution: Risk of
damage to lamp
and reflector!
If
lamp or reflector
touch one another,
they may become
damaged by
scratching. This may
create a line of
weakness, leading to
premature failure of
lamp or reflector.
8
Carefully insert
lamphouse completely
into front housing with a
straight linear
move-
ment (see picture 12).
Ensure that lamp's glass
cover is truly central.
9
To reassemble
lamphead, turn bayonet
socket right (i.e. clock-
wise) until locking pins
slide forward.
Continue turning right.
First, the focus mecha-
nism (see page 52)
reaches its stop position.
Then, after approx. 30°,
the bayonet lock will
engage noticeably and
audibly (see picture 13).
Now, lamphouse is in
place again and
lamphead is ready for
use.
33
HANDLING
Bild/Picture 12
Bild/Picture 13
Summary of Contents for arrilux 400 lighthouse
Page 6: ...Übersicht 6 Übersicht 1 9 8 7 6 5 4 3 2 13 17 16 15 14 10 12 11 18 6 6 DAS PRODUKT ...
Page 72: ...Technische Daten Scheinwerfer 72 Abmessungen Technische Daten PAR LITE A 30 9 B 294 300 ...
Page 73: ...Technical Data of Lampheads 73 Dimensions Technical Data ...
Page 79: ...79 APPENDIX Bild Picture 50 Bild Picture 51 ...
Page 91: ...TÜV GS Zertifikat TÜV GS Certificate 91 APPENDIX TÜV GS Zertifikat TÜV GS Certificate ...
Page 93: ...CB Test Zertifikat CB Test Certificate 93 CB Test Zertifikat CB Test Certificate APPENDIX ...