![ARRI arrilux 400 lighthouse Operating Instructions Manual Download Page 31](http://html.mh-extra.com/html/arri/arrilux-400-lighthouse/arrilux-400-lighthouse_operating-instructions-manual_2975793031.webp)
Inserting Lamp – Relamping
31
Inserting Lamp – Relamping
I
Danger: High Volt-
age!
Switch off bal-
last and disconnect it
from lamphead
before relamping.
I
Danger: Hot Lamp!
Allow lamp to cool
down sufficiently
before relamping.
1
To remove lamp-
house, take bayonet
socket as shown in pic-
ture 6. Turn it left (anti-
clockwise direction) until
it reaches its stop posi-
tion. Continue turning by
approx. 30° to open
bayonet lock.
I
Caution: Risk to
damage lamp and
reflector!
If lamp or
reflector touch one
another, they may
become damaged
by scratching. This
may create a line
of weakness, lead-
ing to premature
failure of lamp or
reflector.
2
Take off lamphouse
carefully with a
straight
linear
movement (see
picture 7).
3
Open lamp-holder
lock (see picture 8) and
carefully remove (used)
lamp by drawing it from
its socket (see picture 9).
¡
Inspect pins of used
lamps: If there are
localised signs of discol-
ouration (caused by
overheating), lamp
holder may have been
damaged and may
shorten lifetime of
lamps.
¡
All contacts of lamp
holder must be dry and
free of contamination or
corrosion when installing
a new lamp.
¡
Fingerprints on lamp
glass will burn in and
reduce its lifetime.
4
Without touching the
lamp glass, using a
clean cotton glove or the
cover supplied by the
lamp manufacturer,
carefully take new lamp
out of its package, hold-
ing it by its base.
5
Clean lamp as stated
in manufacturer’s instruc-
tions, packed with lamp.
We kindly advise you to
follow the operating
instructions supplied with
lamp.
31
HANDLING
Bild/Picture 8
Bild/Picture 9
Summary of Contents for arrilux 400 lighthouse
Page 6: ...Übersicht 6 Übersicht 1 9 8 7 6 5 4 3 2 13 17 16 15 14 10 12 11 18 6 6 DAS PRODUKT ...
Page 72: ...Technische Daten Scheinwerfer 72 Abmessungen Technische Daten PAR LITE A 30 9 B 294 300 ...
Page 73: ...Technical Data of Lampheads 73 Dimensions Technical Data ...
Page 79: ...79 APPENDIX Bild Picture 50 Bild Picture 51 ...
Page 91: ...TÜV GS Zertifikat TÜV GS Certificate 91 APPENDIX TÜV GS Zertifikat TÜV GS Certificate ...
Page 93: ...CB Test Zertifikat CB Test Certificate 93 CB Test Zertifikat CB Test Certificate APPENDIX ...