Lisbona 2
English
05060167 00 09-08-2016
44
13.
How to join the cabinets (Fig.27)
Step
Acti on
1
Disassemble the shoulders (if present).
2
Positi on the cabinets side by side
3
Make sure the alignment pins
3
-
4-6
and the trough coupling
5
are inserted into their respec-
ti ve housings.
5
Att ach the uprights with hook (Fig.28). Insert the Allen wrench supplied with the channel
union kit into the hole made on the back panels.
4
Join the risers and the brackets
A
, using the screws supplied
1
-
2
Pos. Name
Code
1
Screw TCEI M8x120
04711065
2
Nut M8
04230600
3
Alignment pin 4x80
02940652
4
Alignment pin 10x60
02047000
5
Trough coupling
01334013
6
Hook alignment pin
02040256
14.
Electric connecti on
DANGER! Live parts. Electrocuti on.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
ensure that the casing does not come into contact with the electrical panel
Provide a suitable grounding system!
i
The systems must be set up in accordance to the norms that regulate manufacture, installa-
ti on, use, and maintenance foreseen by the norms in force in the country where the refrigera-
ti on system is installed.
To ensure normal operati on, the maximum variati on of the voltage must range b/-
6% of the nominal value.
Liability
Customer
provide a power line to the cabinet connecti on point.
Installer
provide the anchoring devices for all the wires in input and out-
put to/from the cabinet.
ARNEG
ARNEG S.p.A. denies all liability with respect to the user or third
parti es for:
-
damages caused by failures or malfuncti on of the systems
installed upstream of the cabinet
-
damages to the cabinet due to causes arising directly from
malfuncti on of the electrical system
Power
power supply
•
the supply lines of the electric energy should meet the requirements of power
consumpti on of the cabinet chap.9.
•
check that the power line:
-
has wires with suitable cross secti on
-
is protected against over-current, overload and dispersions toward earth in
accordance with the rules in force