Supplied By www.heating spares.co Tel. 0161 620 6677
38
settings - adjustment - problem identification menus
menu
sub
-menu
Par
amet
er
Description
value
default setting
3 BOILER WITH TANK (INTERNAL OR EXTERNAL) AND SOLAR APPLIANCE CONNECTION
3 0 GENERAL SETTING
3 0 0
NOT ACTIVATED
3 0 1
NOT ACTIVATED
3 0 2
NOT ACTIVATED
3 1
Entering access code
Turn the encoder clockwise to select 34 and
press the M
enu
button
3 2 SPECIAL SETTING
3 2 0
Anti-legionella function
0=OFF - 1 = ON
This function avoids the formation of the legionella bacterium wich sometimes develops in pipes and water tanks where the temperature is
included between 0 and 40°C. If the storage temperature remains more than 100 hours less than 59°C and the function is enable, the boiler
is light aan and the storage water is warmed up to 65°C during 30 minutes.
3 2 1
NOT ACTIVATED
Enable only with Clip-In solar connected
(option)
3 2 2
NOT ACTIVATED
3 2 3
Collector delta temp pump ON
from 0 to 30°C
8
3 2 4
Collector delta temp pump OFF
from 0 to 30°C
3 2 5
Minimum collector temp pump ON
from 10 to 90°C
30
2 2 6
Collector kick
ON or OFF
OFF
3 2 7
Recooling function
ON or OFF
OFF
3 2 8
NOT ACTIVATED
3 2 9
Collector frost protection temperature
from -0 to +5°C
-0