Supplied By www.heating spares.co Tel. 0161 620 6677
56
MAINTENANCE GUIDE
MAINTENANCE GUIDE: GENUS HE
3.16 MANUAL AIR VENT
MANUAL AIR VENT
Time
5 min
Tools
1
3.17 MAIN HEAT EXCHANGER
Drain boiler (see 3.3)
Remove the clip and lift the manual air vent from the exchanger
MAIN HEAT EXCHANGER
Tools
Time
20 min
1
Drain boiler (see 3.3). Remove
the four clips and disconnect the
two
pipes
between
the
exchanger
and
pump
and
between the exchanger and left
hand hydraulic block
Isolate the gas supply. Remove
the four screws and disconnect
the gas pipe from the gas valve
Remove the four screws to free
the heat exchanger
2
Pull the heat exchanger towards
you
Remove the clip and lift the
manual air vent
Twist the thermal fuse to
remove
Page. 17 of 24