Supplied By www.heating spares.co Tel. 0161 620 6677
35
settings - adjustment - problem identification menus
Accessing the settings - adjustment - problem identification
menus
The boiler can be used to manage the heating and domestic hot
water production system in its entirety.
Navigation within the menus enables the boiler system +
connected peripheral units to be customised, optimising
operation for maximum comfort and maximum saving. It also
provides important information relating to the efficient operation
of the boiler.
The following menus are available:
The parameters relating to each individual menu are listed in the
following pages.
The various parameters can be accessed and modified using the
M
enu
/o
k
button and the encoder (see fig. below). The description of
the menus and of each individual parameter will be shown on the
display.
On the display, the information relating to the menus and to the
individual parameters are indicated by the figures and by the scrolling
text shown in the figure below.
To access the Menus, open the cover and proceed as follows:
1. Press the M
enu
/o
k
button; the first figure
0
00
will flash on the
display.
. Turn the encoder to select a menu; the text on the display will
indicate the title of the pre-selected menu, for example: “
2
00
-
Boiler parameters”.
3. Press the M
enu
/o
k
button; the first two figures on the display will
flash and the access code will flash, e.g. “
21
0
- Access code”.
Caution!
The menus reserved for qualified technicians may only
be accessed after setting the access code.
4. Press the M
enu
/o
k
button;
222
will appear on the display unit.
5. Turn the encoder in a clockwise direction to select code
234
-
Correct code.
6. Press the M
enu
/o
k
button to select the sub menu; the first two
figures will flash, e.g. “
22
0
”.
7. Turn the encoder to select a sub menu; the text on the display
will indicate the title of the pre-selected sub menu, for example:
“
23
0
- Heating - Part 1”.
8. Press the M
enu
/o
k
button to access the sub menu parameters; the
three figures will flash, for example: “
230
”.
9. Turn the encoder to select a parameter; the text on the display
will indicate the title of the pre-selected parameter, for example:
“
231
- Max. Adjustable Heating Power”.
10. Press the M
enu
/o
k
button to access the parameter; the display will
indicate the value, e.g “
70
”.
Note:
The parameter value will be displayed for 0 seconds, then
will begin to flash in alternation with the parameter, e.g. “
70
>
231
.
11. Turn the encoder to select the new value, e.g. “
75
”.
1. Press M
enu
/o
k
to save the change or press e
sc
to exit without
saving.
To exit, press the e
sc
button until the normal display screen is
restored.
For menus which do not require the access code, it is possible to pass
directly from the menu to the sub menu.
ABCDEFGHIL123456
0 Time-Date-Language
See manual user’s
0
0
Set Dispaly Language
0
1
Set Time-Date
0
British Summer Time
1 Set Timer
See manual user’s
2 Boiler Parameter
1
Service code (34)
General setting
3
C.H. Parameters - Part 1
4
C.H. Parameters - Part 1
5
Domestic Hot Water
9
Menù Reset to factory setting
3 Solar & Storage
3
0
General setting
3
1
Service code (34)
3
Special setting
4 Zone 1 Parameters
4
0
Set-point Zone1
4
1
Service code (34)
4
Zone 1 Setting
4
3
Diagnostics
4
4
Zone device mangement
5
Zone 2 Parameters
5
0
Set-point Zone
5
1
Service code (34)
5
Zone Setting
5
3
Diagnostics
5
4
Zone device mangement
5
5
Multizone
7 Test & Utilities
8 Service Parameter
8
1
Service code (34)
8
Boiler
8
3
Boiler Temperature
8
4
Solar & Storage
8
5
Service
8
6
Statistics
8
7
E@sy - NOT ACTIVE
8
8
Error History
Encoder
(adjustment
knob)
Enables the
set values to
be increased
or decreased
Menu/Ok-
button