Supplied By www.heating spares.co Tel. 0161 620 6677
37
settings - adjustment - problem identification menus
menu
sub
-menu
par
amet
er
description
value
default setting
2 4 BOILER PARAMETER - PART 2
2 4 0
NOT PRESENT
2 4 1
NOT PRESENT
2 4 2
NOT PRESENT
2 4 3
Post-ventilation after heating request
0 = OFF
1 = ON
0
2 4 4
Time delay after heating temperature increase
from 0 to 60 minutes
16
activated only with thermostat On/Off and
heating control activated (parameter 41 or 51
= 01
This parameter allows the time delay to be set before automatic increase of the flow temperature calculated in increments of 4°C (max 1°C). If this
parameter retains the value 00, this function is not active.
2 4 5
NOT PRESENT
2 4 6
NOT PRESENT
2 4 7
Device indicator for heating circuit pressure
0 =
temperature sensor only
1 = pressure switch at mini-
mum
= pressure sensor
1
RESERVED FOR TECHNICAL ASSISTANCE Only if the
PCB is changed
2 4 8
NOT PRESENT
2 5 DOMESTIC HOT WATER PARAMETER
2 5 0
COMFORT function
0 = deactivated
1 = timed
= always on
0
Timer = activated for 30 minutes after domestic
hot water draw-off
The appliance allows the hot water heating comfort to be increased via the “COMFORT” function.
This function keeps the secondary exchanger temperature stable when the boiler is not in use. When the function is active,
the display shows COMFORT
Note: this function can be activated and deactivated by pressing the COMFORT button
2 5 1
Comfort Anti-cycling Time
from 0 to 10 minutes
0
2 5 2
Hot water flow delay
from 5 to 00 (0.5 to 0
seconds)
5
Anti "water hammering"
2 5 3
Extinction of the burner in domestic hot water
0 = anti-scale (stop at > 67°C)
1 = + 4°C /setting
0
2 5 4
Post-circulation and post-ventilation after a
domestic hot water draw-off
0 = OFF
1 = ON
0
OFF = 3 minutes post-circulation and post-ventilation after domestic hot water
draw-off if the boiler temperature measured requires it.
ON = always on for 3 minutes post-circulation and post-ventilation after domestic
hot water draw-off.
2 5 5
Domestic hot water timer
from 0 to 60 minutes
0
2 9 RESET MENU 2
2 9 0
Automatically resetting to the default setting in
menu
Reset
OK = yes
ESC = no
To reset all default parameter settings, press the
MENU button