Supplied By www.heating spares.co Tel. 0161 620 6677
30
commissioning
Basic set up instructions - Timer and Range Rating Power
When the GENUS HE appliance is first turned on, the language
(optional), central heating timer and output power must be set
up.. The following instructions detail the basic set up procedure
which will satisfy most standard boiler installations. For more
complicated installations, i.e. outside temperature sensing
etc. additional settings may need to be altered to match the
performance to the system requirements.
To begin, switch the electrical supply to the boiler on, press the
ON/OFF button on the control panel once to switch the appliance
on.
Setting the language
Press the Menu/Ok button once (a flashing 0 appears on the left
side of the display);
Press the Menu/Ok button again (00 appears on the display, the
second 0 is flashing);
Press the Menu/Ok button again. The language appears at the
bottom of the display.
Rotate the left hand control knob until the desired language is
displayed;
Press Menu/Ok to save the setting;
‘Value Saved’ is displayed;
Press Esc twice to return to the normal display..
Setting the time, date, year and day of the week
Note: The date is in yyyy/mm/dd format.
Always use the left hand control knob to change
settings.
Press the Menu/Ok button once (a flashing 0 appears on the left
side of the display);
Press the Menu/Ok button again (00 appears on the display, the
second 0 is flashing);
Rotate the control knob to change the display to 01. ‘Time + Date’
is displayed at the bottom of the screen;
Press the Menu/Ok button, the days of the week will appear on
the screen and hours will flash;
Rotate the controll knob to select the hour of the day and then
press the
mode
button;
The minutes will flash. Rotate the control knob to select the
minutes and press the
mode
button;
The year will flash. Rotate the control knob to select the year and
press the
mode
button;
The month will flash. Rotate the control knob to select the month
and press the
mode
button;
The day of the month will flash. Rotate the control knob to select
the day of the month and press the
mode
button;
The day of the week will flash. Rotate the control knob to select
the day of the week;
Press the Menu/Ok button to save the settings;
‘Value saved’ is displayed;
Press Esc twice to return to the normal display.
Setting the time clock (same timed programme every day)
Using pre- set time settings
Press the Menu/Ok button once (a flashing 0 appears on the left
side of the display);
Rotate the control knob to change the 0 to 01. ‘Set Timers’ is
displayed at the bottom of the screen;
Press the Menu/Ok button. 101 appears.
Rotate the control knob until 106 appears on the screen. ‘Pre-set
timers’ appears at the bottom of the display.
Press the Menu/Ok button. It is now possible to select one of
three options: Preset Timers 1, or 3.
Monday to Sunday
Preset
Timer 1
On
5:30
Off
22:00
Preset
Timer 2
On
6:00
Off
8:00
On
11:30
Off
13:00
On
17:00
Off
22:00
Preset
Timer 3
On
6:00
Off
8:00
On
16:00
Off
22:00
To select one of the preset times, rotate the control knob which
scrolls between the three options;
Press Menu/Ok to save the selected option;
‘Value Saved’ is displayed;
Press ‘Esc’ twice to return to the normal display.
To display the timer settings, the boiler MUST be in ‘Winter’
mode, i.e. the radiator symbol (to the left of the tap symbol)
is displayed.
To activate the ‘Winter’ mode, press the
mode
button once, until
the radiator symbol is displayed;
To initiate the timer press the button, the timer display is shown
at the top of the screen;
For constant heating (‘Winter’ mode only - see above) press the
so the timer display disappears. The boiler will now operate the
central heating constantly;
To return to the timer function, press the button. The timer
display will reappear.
Selecting your own times options (Monday to Sunday)
The time clock is initially set with all time segments selected
for the 24 hour period i.e. constant operation.
If a pre-set time pattern has been selected, this will be
displayed.