CLI Manager
28
CLI>link
ArrayDevice Element (0x17):
========================================
NAME
PHY
NGO EDFB
MAX
MIN
TYPE
ADDRESS
SLOT 01
4
6G
6G 12G
3G
SATA
5001B469-189AE00D
SLOT 02
5
6G
12G
12G
3G
SAS
5011B469-189AE00C
SLOT 03
6
6G
6G 12G
3G
SATA
5011B469-189AE00E
SLOT 04
7
6G
6G 12G
3G
SATA
5011B469-189AE00F
SLOT 05
8
6G
6G 12G
3G
SATA
5011B469-189AE009
SLOT 06
9
6G
6G 12G
3G
SATA
5011B469-189AE008
SLOT 07
10
6G
6G 12G
3G
SATA
5011B469-189AE00A
SLOT 08
11
6G
6G 12G
3G
SATA
5011B469-189AE00B
CLI>edfb on ;;;;; set all drives on
CLI>st
Reset or PowerCycle
…….
• TH Command
The th command allows you to set the operate device tempera-
ture warning limit. Typical parameters include: High-Warn and
Low-Warn are warning temperature in Celsius.
Syntax
CLI>th Index High-Warn Low-Warn
Example:
CLI>th
Temperature Element (0x04):
========================================
NAME
ID
CT(‘C)
HTW
LTW
OTWarn
ENC. Temp
01
30
60
5
No
Chip Temp
02
64
85
5
No