DMX ETH Manual
page 51
rev 1.16
[2-7] – Driver write
failure
RR
Read driver parameters
OK
RZ
Get return zero enable. Used during homing
0 or 1
RZ=[0 or 1]
Set return zero enable. Used during homing
OK
RW
Write driver parameters
OK
SASTAT[0,1]
Get standalone program status
0 – Stopped
1 – Running
2 – Paused
4 – In Error
0-4
SA[LineNumber]
Get standalone line
LineNumber: [0,7649]
SA[LineNumber]=[Value] Set standalone line
LineNumber: [0, 7649]
SCV
Returns the s-curve control
0 or 1
SCV=[0 or 1]
Enable or disable s-curve. If disabled, trapezoidal
acceleration/ deceleration will be used.
OK
SL
Returns StepNLoop enable status
0 – StepNLoop Off
1 – StepNLoop On
SL=[0 or 1]
Enable or disable StepNLoop Control
OK
SLA
Returns maximum number of StepNLoop control
attempt
28-bit number
SLA=[value]
Sets maximum number of StepNLoop control attempt
OK
SLE
Returns StepNLoop correction range value.
28-bit number
SLE=[value]
Sets StepNLoop correction range value.
OK
SLR
Returns StepNLoop ratio value
[0.001 – 999.999]
SLR=[factor]
Sets StepNLoop ratio value. Must be in the range [0.001
– 999.999]
OK
SLS
Returns current status of StepNLoop control
See Table 7.6
SLT
Returns StepNLoop tolerance value
32-bit
SLT=[value]
Sets StepNLoop tolerance value.
OK
SLOAD
Returns RunOnBoot parameter
See Table 7.9
SLOAD=[0 or 1]
Set RunOnBoot parameter
See Table 7.9
SPC[0,1]
Get program counter for standalone program
[0-1784]
SR[0,1]=[Value]
Control standalone program:
0 – Stop standalone program
1 – Run standalone program
2 – Pause standalone program
3 – Continue standalone program
OK
SSPD[value]
On-the-fly speed change. In order to use this command,
S-curve control must be disabled. Use SCV command to
enable and disable s-curve acceleration/ deceleration
control. Note that an “=” sign is not used for this
command.
OK
SSPDM
Return on-the-fly speed change mode
[0-9]
SSPDM=[value]
Set on-the-fly speed change mode
OK
STOP
Stops the motor using deceleration if in motion.
OK
STORE
Store settings to flash memory
OK
T[value]
On-the-fly target change
OK
TOC
Get time-out counter (ms)
32-bit number
TOC=[value]
Set time-out counter (ms)
OK
V[0-99]
Read variables 0-99
28-bit number
V[0-99]=[value]
Set variables 0-99
OK
Summary of Contents for DMX-ETH
Page 13: ...DMX ETH Manual page 13 rev 1 16 Figure 4 1 Torque Curve NEMA 23 Figure 4 2...
Page 14: ...DMX ETH Manual page 14 rev 1 16 Figure 4 3...
Page 17: ...DMX ETH Manual page 17 rev 1 16 DMX ETH Interface Circuit Figure 5 2...
Page 21: ...DMX ETH Manual page 21 rev 1 16 Main Control Screen Figure 6 3 A B C D E F L K J H M G I...