The motor is now past the home input by the amount defined by the home
correction amount (
HCA
). The motor now moves back towards the home switch
at low speed.
F.
The home input is triggered again, the position counter is reset to zero and the
motor stops immediately
Limit Only
Use the
L+/L-
command. Figure 7.5 shows the homing routine.
Figure 7.5
A.
Issuing a limit home command starts the motor from low speed and accelerates to
high speed.
B.
The corresponding limit is triggered and the motor stops immediately.
C.
The motor reverses direction by the amount defined by the limit correction
amount (
LCA
) at high speed.
D.
The zero position is reached.
Z-index only
Use the
Z+/Z-
command. Figure 7.6 shows the homing routine.
Figure 7.6
A.
Issuing the command starts the motor at low speed.
B.
Once the z-index pulse is found, the motor stops and the position is set to zero.