![Arcus DMX-CAN-23 Manual Download Page 50](http://html1.mh-extra.com/html/arcus/dmx-can-23/dmx-can-23_manual_2965572050.webp)
DMX-CAN Manual
page 50
rev 1.6
Figure 8.1
A:
Object 200D
h
activated, indicating that an error need to be cleared.
B:
The device has reset 200D
h
after all errors have been cleared.
Object Description
Index
Name
Data Type
Value Range
Access
200D
h
Clear Error
Unsigned 8
0 - 1
Read/Write
Table 8.38
Object 200E
h
: Perform Store
This object stores all relevant settings and parameters to non-volatile flash. To store to
flash, write a 1 to this object. The device well then save all parameters and store them to
flash and the object will be reset to zero, indicating that the store has been performed. See
below for a timing diagram:
Figure 8.2
A:
Object 200E
h
activated, indicating that all parameters need to be stored to flash.
B:
The device has reset 200E
h
after all parameters have been saved successfully.
Object Description
Index
Name
Data Type
Value Range
Access
200E
h
Perform Store
Unsigned 8
0 - 1
Read/Write
Table 8.39
The following objects are saved to flash.
Object
Description
2000
h
Alarm/In Position Enable
2001
h
StepNLoop Parameters
2004
h
Driver Settings
2005
h
Digital Output Boot
2006
h
Enable Output Boot
200A
h
Communication Type