![Arcus DMX-CAN-23 Manual Download Page 42](http://html1.mh-extra.com/html/arcus/dmx-can-23/dmx-can-23_manual_2965572042.webp)
DMX-CAN Manual
page 42
rev 1.6
DN
Device name
DOBOOT
DO configuration at boot-up
EDO
Enable in-pos/alarm outputs
EOBOOT
EO configuration at boot-up
LCA
Limit correction amount
POL
Polarity settings
RT
ASCII response type
SL, SLR, SLE, SLT,
SLA, SLM
StepNLoop parameters
Table 7.10
Default Settings
Following are the factory default settings when then unit is shipped from the factory.
Command
Parameter Description
Value
BR
Baud-rate (for CANOpen)
125000 bps
CM
Communication Method
RS-232
CURI
Idle Current
1000 mA
CURR
Run Current
1600 mA
CURT
Idle Time
500 mSec
DB
Baud Rate (for RS-232/RS-485)
9600 bps
DN
Device ID
DMC01
DOBOOT
Digital Output Boot-up State
7
EDO
Alarm/ In Pos Output Mode
Enabled
EOBOOT
Enable Output Boot-up State
0
LCA
Limit Correction Amount
1000
NID
Node ID (for CANOpen)
1
POL (bit 1)
Direction Polarity
CW
POL (bit 4)
Limit Polarity
Active Low
POL (bit 5)
Home Polarity
Active Low
POL (bit 6)
Latch Polarity
Active Low
POL (bit 7)
In Position Output Polarity
Active Low
POL (bit 8)
Alarm Output Polarity
Active Low
RT
Response type
Do Not Append
SL
StepNLoop
Enabled
SLA
StepNLoop Maximum Attempt
10
SLE
StepNLoop Error Range
1000
SLM
StepNLoop Idle Tolerance
5
SLT
StepNLoop Tolerance Range
20