background image

Manufacturer’s Warranty

Section 9

Manufacturer’s Warranty

Our Commitment

VIQUA is committed to ensuring your experience with our products and organization exceeds your expectations. We have 

manufactured your UV disinfection system to the highest quality standards and value you as our customer. Should you 

need any support, or have questions about your system, please contact our Technical Support team at 1.800.265.7246 or 

[email protected]

 and we will be happy to assist you. We sincerely hope you enjoy the benefits of clean, safe 

drinking water after the installation of your VIQUA disinfection system.

How to Make a Warranty Claim

Note: 

To maximise the disinfection performance and reliability of your VIQUA product, the system must be properly sized, 

installed and maintained. Guidance on the necessary water quality parameters and maintenance requirements can 

be found in your Owner’s Manual. 

In the event that repair or replacement of parts covered by this warranty are required, the process will be handled by your 

dealer. If you are unsure whether an equipment problem or failure is covered by warranty, contact our Technical Support 

team at 1.800.265.7246 or e-mail 

[email protected]

. Our fully trained technicians will help you troubleshoot the 

problem and identify a solution. Please have available the model number (system type), the date of purchase, the name of 

the dealer from whom you purchased your VIQUA product (“the source dealer”), as well as a description of the problem 

you are experiencing To establish proof of purchase when making a warranty claim, you will either need your original 

invoice, or have previously completed and returned your product registration card via mail or online.

Specific Warranty Coverage

Warranty coverage is specific to the VIQUA range of products. Warranty coverage is subject to the conditions and 

limitations outlined under “

General Conditions and Limitations

”.

Ten-Year Limited Warranty for VIQUA UV Chamber

VIQUA warrants the UV chamber on the VIQUA product to be free from defects in material and workmanship for a period 

of ten (10) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective 

VIQUA UV chamber. Please return the defective part to your dealer who will process your claim.

Three-Year Limited Warranty for Electrical and Hardware Components

VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship 

for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any 

defective parts covered by the warranty. Please return the defective part to your dealer who will process your claim.

One-Year Limited Warranty for UV lamps, Sleeves, and UV Sensors

VIQUA warrants UV lamps, sleeves, and UV sensors to be free from defects in material and workmanship for a period of 

one (1) year from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts 

covered by the warranty.Your dealer will process your claim and advise whether the defective item needs to be returned for 

failure analysis.

Note: 

Use only genuine VIQUA replacement lamps and sleeves in your system. Failure to do so may seriously 

compromise disinfection performance and affect warranty coverage.

General Conditions and Limitations

None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor 

scratches or imperfections that do not materially impair the operation of the product. The warranties also do not cover 

products that are not installed as outlined in the applicable Owner’s Manual.
Parts repaired or replaced under these warranties will be covered under warranty up to the end of the warranty period 

applicable to the original part.
The above warranties do not include the cost of shipping and handling of returned items.The limited warranties described 

above are the only warranties applicable to the VIQUA range of products. These limited warranties outline the exclusive 

remedy for all claims based on a failure of or defect in any of these products, whether the claim is based on contract, tort 

(including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether written, oral, 

implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any 

of these products.
VIQUA does not assume any liability for personal injury or property damage caused by the use or misuse of any of the 

above products. VIQUA shall not in any event be liable for special, incidental, indirect or consequential damages. VIQUA’s 

liability shall, in all instances, be limited to repair or replacement of the defective product or part and this liability will 

terminate upon expiration of the applicable warranty period.

14

Summary of Contents for SC200-A

Page 1: ...Owner s Manual Powered by Models SC200 A SC410 A 520192 R_RevK...

Page 2: ...should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equipme...

Page 3: ...l for VERY hot water when flow is started 1 2 Safety Precautions DANGER Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipmen...

Page 4: ...n avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations an...

Page 5: ...1 O ring 410867 Used on all systems 2 214 fused quartz sleeves with fire polished ends QS 001 SC200 A QSO 410 SC410 A 3 Retaining Nut RN 001 Used on all systems 4 Hard glass coated Sterilume HO UV la...

Page 6: ...5 micron sediment filter must precede the disinfection system Ideally the disinfection system should be the last treatment the water receives before it reaches the faucet Procedure 1 The use of a by...

Page 7: ...nection point to prevent any water from potentially leaking onto the controller by means of a leak at a connection point or a sweating system Make sure you allow for a drip loop as shown in Figure 5 o...

Page 8: ...2 1 2 2 2 Shut off the water supply Close each faucet 3 1 2 Remove filter cartridge s 4 Household 5 25 Bleach Solution BLEACH x2 2 Pour 2 cups of household bleach solution into the filter housing s No...

Page 9: ...main power source and allow the unit to cool for 10 minutes 3 1 2 Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector 4 Hg UV Remove the lamp in upward directi...

Page 10: ...then replace the sleeve 6 Reinstall the quartz sleeve in the chamber allowing the sleeve to protrude an equal distance at both ends of the chamber Slide supplied O rings onto each end of the quartz sl...

Page 11: ...refer to Section 4 1 5 1 3 Resetting Lamp Life Refer to Section 4 1 Note Even though the alarm on the system can be deferred for a period of time it is important to address each and every alarm condit...

Page 12: ...system must have a bacterial free distribution system to work effectively Refer to Section 3 1 Possible break through of sediment through pre filter Have source water tested for turbidity may need st...

Page 13: ...1 MNPT 3 4 FNPT Combo 3 4 FNPT 1 MNPT Shipping Weight 5 1 kg 11 3 lbs 6 8 kg 15 0 lbs Electrical Voltage 100 240 V 50 60Hz 100 240 V 50 60Hz Max Current 1 5 Amp 1 5 Amp Power Consumption 35 W 60 W La...

Page 14: ...rdware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During th...

Page 15: ...Supporter par Mod les SC200 A SC410 A Manuel d utilisation Supporter par 520192 R_RevK...

Page 16: ...ine VIQUA Il a t d montr que l utilisation de lampes de rechange qui ne sont pas d origine et largement disponibles endommage le module du dispositif de commande du syst me de d sinfection par UV VIQU...

Page 17: ...nnect une prise correctement mise la terre prot g e par un disjoncteur de fuite de terre DFT Ce symbole indique qu il y a un risque potentiel d eau TR S chaude lorsque l coulement commence DANGER Le n...

Page 18: ...mercure Si la lampe se brise vitez d inhaler ou d ing rer des d bris ou m me d exposer vos yeux et votre peau N utilisez jamais d aspirateur pour nettoyer une lampe bris e car cela pourrait r pandre l...

Page 19: ...0867 Utilis sur tous les syst mes 2 manchons en quartz fondu 214 avec extr mit s polies au feu QS 001 SC200 A QSO 410 SC410 A 3 crou de blocage RN 001 Utilis sur tous les syst mes 4 Lampes UV en verre...

Page 20: ...e de d sinfection devrait tre le dernier traitement re u par l eau avant qu elle arrive au robinet Proc dure 1 L utilisation d un ensemble de d rivation est recommand e dans le cas o le syst me n cess...

Page 21: ...tif de commande 5 Installez la lampe UV Consultez la Section 4 1 6 Lorsque tous les raccords de plomberie sont termin s tournez lentement l alimentation en eau et v rifiez les fuites ventuelles La cau...

Page 22: ...ra nera l oxydation de ces contaminants et pourrait n cessiter le rin age r p t du r servoir d eau chaude Cette ventualit doit tre trait e ind pendamment selon la proc dure de d marrage pour tout autr...

Page 23: ...mplacement de la lampe UV 1 Couper la canalisation d eau vers la chambre et rel cher la pression du syst me avant de proc der l entretien 2 0 30 15 45 10 min D brancher la source d alimentation princi...

Page 24: ...age inf rieur le ressort flottant et le joint torique 3 1 2 D poser l crou de blocage sup rieur et le joint torique 4 D poser le manchon de quartz 5 Mild Acid Nettoyer le manchon en quartz avec un chi...

Page 25: ...teur consultez la Section 4 1 5 1 3 R initialisation de la dur e de vie de la lampe Consultez la Section 4 1 Remarque m me si l alarme du syst me peut tre report e pendant un certain temps il est impo...

Page 26: ...st en place recherchez des coupures ou usures nettoyez le joint torique humidifiez le l eau lubrifiant et reposez le remplacez le si n cessaire 410867 Condensation sur la chambre UV caus e par une hum...

Page 27: ...Courant max 1 5 amp res 1 5 amp res Consommation lectrique 35 W 60 W Watts de la lampe 25 W 45 W Pression maximale de fonctionnement 125 psi 861 kPa 125 psi 861 kPa Pression minimale de fonctionnemen...

Page 28: ...VIQUA garantit les composants mat riels et lectriques dispositif de commande contre tout d faut de mati re et de main d uvre pour une dur e de trois 3 ann es compter de la date d achat Dans cette p ri...

Page 29: ...Desarrollado por Modelos SC200 A SC410 A Manual del propietario Desarrollado por 520192 R_RevK...

Page 30: ...eposici n VIQUA originales de f brica Se ha demostrado que el uso de las l mparas de reposici n no originales disponibles ampliamente en el mercado da a el m dulo de control del equipo de desinfecci n...

Page 31: ...UY caliente cuando se inicie el flujo PELIGRO El incumplimiento de estas instrucciones puede ocasionar lesiones graves o la muerte Descarga el ctrica Para evitar posibles descargas el ctricas se deben...

Page 32: ...ercurio En caso de rotura evite inhalar o ingerir los restos y evite la exposici n de ojos y piel Nunca utilice una aspiradora para limpiar una l mpara rota ya que podr a dispersar el mercurio vertido...

Page 33: ...go QS 001 SC200 A QSO 410 SC410 A 3 Tuerca de retenci n RN 001 Se utiliza en todos los sistemas 4 L mparas UV Sterilume HO revestido de cristal duro para una vida til prolongada y de calidad constante...

Page 34: ...i n deber a ser el ltimo tratamiento que reciba el agua antes de llegar al grifo Procedimiento 1 Se recomienda el uso de un conjunto de desv o en el caso de que el sistema requiera mantenimiento fuera...

Page 35: ...sulte Secci n 4 1 6 Cuando se hayan realizado todas las conexiones de tuber as conecte el suministro de agua lentamente y compruebe si hay fugas La causa m s probable de fugas est en la junta t rica E...

Page 36: ...a la oxidaci n de dichos contaminantes y es posible que sea necesaria una limpieza repetida del tanque de agua caliente Esta eventualidad se debe tratar de forma independiente bajo el procedimiento de...

Page 37: ...y libere la presi n del sistema antes de realizar el servicio 2 0 30 15 45 10 min Desconecte la fuente de alimentaci n principal y deje que la unidad se enfr e durante 10 minutos Desconecte la fuente...

Page 38: ...junta t rica de la parte inferior 3 1 2 Quite la tuerca de retenci n y la junta t rica de la parte superior 4 Quite la vaina tubular de cuarzo 5 Mild Acid Limpie la vaina tubular de cuarzo con un tra...

Page 39: ...onsulte la Secci n 4 1 5 1 3 Reinicio de la vida de la l mpara Consulte Secci n 4 1 Nota Aunque la alarma del sistema se puede aplazar durante un per odo de tiempo es importante que se responda a toda...

Page 40: ...retenci n o el sensor UV Aseg rese de que la junta t rica est en su sitio compruebe si hay cortes o abrasiones l mpiela humed zcala con agua o lubricante y vuelva a instalarla o sustit yala si es nec...

Page 41: ...ltaje 100 240 V 50 60 Hz 100 240 V 50 60 Hz Corriente m xima 1 5 Amp 1 5 Amp Consumo de energ a 35 W 60 W Vatios de la l mpara 25 W 45 W Presi n m xima de funcionamiento 125 psi 861 kPa 125 psi 861 kP...

Page 42: ...ponentes el ctricos controlador y de hardware estar n libres de defectos de material y mano de obra durante un per odo de tres 3 a os desde la fecha de compra Durante este per odo VIQUA reparar o reem...

Page 43: ...43 Esta p gina est en blanco de forma intencional...

Page 44: ...25 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US et Canada seulement t 31 73 747 0144 Europe seulement f 1 519 763 5069 Courriel info viqua com www viqua com 425 Clair...

Reviews: