2
Note:
Dosages based on 95% UVT at end of lamp life (0.80 EOLL).
Section 8
Specifications
Model
SC200-A
SC410-A
Flow Ra
te
1
US Public Health 16 mJ/cm
2
15 gpm (56.8 lpm) (3.4 m
3
/hr)
29.4 gpm (111.2 lpm) (6.7 m
3
/hr)
VIQUA Standard 30 mJ/cm
2
8 gpm (30.3 lpm) (1.8 m
3
/hr)
15.7 gpm (59.3 lpm) (3.6 m
3
/hr)
NSF/EPA 40 mJ/cm
2
6 gpm (22.7 lpm) (1.4 m
3
/hr)
11.7 gpm (44.5 lpm) (2.7 m
3
/hr)
Overall Dimensions
34.3 cm x 8.9 cm (13.5” x 3.5”)
55.4 cm x 8.9 cm (21.8” x 3.5”)
Inlet/Outlet Port Size
3/4” FNPT/Combo 3/4” FNPT & 1” MNPT
3/4” FNPT/Combo 3/4” FNPT & 1” MNPT
Shipping Weight
5.1 kg (11.3 lbs)
6.8 kg (15.0 lbs)
Electrical
Voltage
100-240 V / 50/60Hz
100-240 V / 50/60Hz
Max. Current
1.5 Amp
1.5 Amp
Power Consumption
35 W
60 W
Lamp Watts
25 W
45 W
Maximum Operating Pressure
125 psi (861 kPa)
125 psi (861 kPa)
Minimum Operating Pressure
15 psi (103 kPa)
15 psi (103 kPa)
Ambient Water Temperature
2-40 ºC (36-104 ºF)
2-40 ºC (36-104 ºF)
Lamp Type
Sterilume™-HO (High-output)
Sterilume™-HO (High-output)
Visual “Power-On”
Yes
Yes
Audible Lamp Failure
Yes
Yes
Lamp Replacement Reminder
Yes
Yes
Visual Lamp Life Remaining
Yes
Yes
Total Running Time
Yes
Yes
254nm UV Monitor
No
No
Solenoid Output (Solenoid not incl.)
No
No
Chamber Material
304 SS
304 SS
Flow rates stated @ 95% UVT EOL
13
Summary of Contents for SC200-A
Page 1: ...Owner s Manual Powered by Models SC200 A SC410 A 520192 R_RevK...
Page 15: ...Supporter par Mod les SC200 A SC410 A Manuel d utilisation Supporter par 520192 R_RevK...
Page 29: ...Desarrollado por Modelos SC200 A SC410 A Manual del propietario Desarrollado por 520192 R_RevK...
Page 43: ...43 Esta p gina est en blanco de forma intencional...