Troubleshooting
Section 6
Troubleshooting
Symptom
Possible Causes
Solutions
•
Run water until it return to ambient temperature.
•
Install temperature management valve
•
Ensure system has been installed on its own circuit, as other equipment may be drawing power
away from UV (ie. pump or fridge).
•
UV system should not be installed on a circuit which is incorporated into a light switch.
DISPLAY FAULT MODES
•
Lamp life expired - countdown is at “0” days
•
Press reset button for a deferred alarm, replace UV lamp
•
Controller is in lamp failure mode
•
Power system down, allowing it to reset itself; apply power in order to confirm that the controller is able to power lamp
•
Check to see if there is sufficient power to the UV system
High Bacteria
Counts
Quartz sleeve is stained or dirty
Clean sleeve with scale cleaner and eliminate source of staining problem (ie. soften hard water,
refer to
Section 4.2
.
Change in feed water quality
Have source water tested to ensure that water quality is still within allowable limits for this system.
Contamination in water lines after UV
system
It is imperative that effluent water stream be shocked with chlorine (bleach) before water leaves UV
system - disinfection system must have a bacterial free distribution system to work effectively. Refer
to
Section 3.1
Possible break-through of sediment
through pre-filter
Have source water tested for turbidity - may need stepped filtration in order to catch all sediment
entering water system (20 micron filter followed by a 5 micron filter followed by UV system).
Heated Product
Water
Common problem caused by
infrequent use of water
Water Appears
Milky
Caused by air in the water lines
Run water until air is purged.
Chamber Leaking
Water
Problem with O-ring seal (on retaining
nut and/or UV sensor)
Ensure O-ring is in place, check for cuts or abrasions, clean O-ring, moisten with water/ lubricant
and re-install, replace if necessary (410867).
Condensation on chamber caused by
excessive humidity & cold water
Check location of disinfection system and control humidity.
Inadequate inlet/outlet port
connections
Check thread connections, reseal with Teflon
®
tape and re-tighten.
System Shutting
Down
Intermittently
Interrupted controller
Lamp Failure
Alarm on - New
Lamp
Loose connection between lamp and
connector
Disconnect lamp from connector and reconnect, ensuring that a tight fit is accomplished
Moisture build up in connector may
keep lamp and connector from making
a solid connection
Eliminate chance of any moisture getting to the connector and/or lamp pins
LED display reads “A3”
LED display is blank
12
Summary of Contents for SC200-A
Page 1: ...Owner s Manual Powered by Models SC200 A SC410 A 520192 R_RevK...
Page 15: ...Supporter par Mod les SC200 A SC410 A Manuel d utilisation Supporter par 520192 R_RevK...
Page 29: ...Desarrollado por Modelos SC200 A SC410 A Manual del propietario Desarrollado por 520192 R_RevK...
Page 43: ...43 Esta p gina est en blanco de forma intencional...