Rise
™
Installation Guide 02
IMPORTANT INFORMATION
Safety information
This appliance can be used by children aged
from 3 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be
made by children without supervision.
This product must be installed by a competent
person in accordance with all relevant current
local and national Water Supply Regulations.
ALL PRODUCTS REQUIRING AN ELECTRICAL
CONNECTION MUST BE INSTALLED BY A
QUALIFIED PERSON FOLLOWING THE
LATEST REVISION OF THE ELECTRICAL
WIRING REGULATIONS, BOTH NATIONAL
AND LOCAL AND CERTIFIED TO CURRENT
BUILDING REGULATIONS.
This system should be installed so that other
taps or appliances operated elsewhere within
the premises do not significantly affect the flow.
The Quartz Smart Valve
™
must not be used with
a hot water supply temperature of over 65ºC. If
the maximum hot water temperature is likely to
rise above 65ºC then a Thermostatic Blending
Valve must be used.
The Quartz Smart Valve
™
is supplied factory
pre-set at maximum temperature of 45ºC.
The maximum temperature is fully adjustable
to suit site conditions. If adjusted, we
recommend the outlet temperature is set
to a MAXIMUM of 46ºC.
The Quartz Smart Valve
™
must be installed in an
accessible location for servicing and maintenance.
The Quartz Smart Valve
™
must not be installed
in situations where either the ambient
temperature is likely to exceed 40ºC or where
freezing may occur.
The controller must not be installed in situations
where the ambient temperature is likely to fall
below 5ºC or rise above 40ºC.
We do not recommend the use of a controller
in steam therapy facilities.
This appliance must be earthed.
Cables must be protected by a suitably sized
conduit or trunking to avoid risk of damage and
to allow removal for service and maintenance
purposes
.
Ensure that the conduit is run to avoid the
controller fixing holes.
Surface mounted cables must also be protected
by a suitable approved conduit, even in a loft,
where there may be a risk of damage from vermin.
The power lead must only be replaced by the
manufacturer or his accredited agent.
The controller is supplied from a safety low
voltage source.
This product is suitable for domestic use only.
Aqualisa products are supplied complete with
a 1 year guarantee that can be upgraded by
registering the product with Aqualisa.
See www.aqualisa.co.uk/guarantee for details.
Installation of the pumped Quartz Smart
Valve
™
(for gravity stored systems)
The pumped Quartz Smart Valve
™
shower
system is designed to operate up to a maximum
static pressure of 100kPa ((1 bar)(10 metres
head)(14.5psi)). Under no circumstances must
the pumped Quartz Smart Valve
™
be connected
directly to the water main or in line with another
booster pump.
The minimum actual capacity of the cold
water storage cistern should be not less than
225 litres (50 gallons). The capacity of the hot
water cylinder must be capable of meeting
anticipated demand.