Rise
™
Installation Guide 17
Loosen the single fixing screw on the top of the Quartz Smart
Valve
™
and then carefully tilt the lid up and off the location lugs,
and set the lid aside.
Connect the low voltage, 10m data cable into the socket adjacent
to the temperature adjuster as indicated on the label.
Feed the cable out of the Quartz Smart Valve
™
ensuring it is
correctly routed within the data cable channel.
Quartz Digital exposed with adjustable head installation instructions
Page 13
Connect the low voltage data cable into the
socket adjacent to the temperature adjuster
as indicated on the label. Feed the cable out of
the processor box ensuring it is correctly
routed within the data cable channel.
22
A further data cable socket has been provided
for use with the secondary Digital remote
control or Digital diverter. This can be accessed by carefully snapping and
removing the entry pillar and connecting the cable as described above.
!
Unscrew the single fixing on top of the
processor box and then carefully tilt the lid up
and off the location lugs and pull the lid clear.
21
Connect the power to the processor and press
the ‘Start/stop’ button on the controller to turn
the shower on. Ensuring the hose washers are
fitted at either end of the shower hose, attach
the hose and flush the system through for 15
seconds to clear any debris. Turn the shower off
and isolate from the electricity supply.
23
A further data cable socket has been provided for use with a remote control or diverter.
This can be accessed by carefully snapping and removing the entry pillar and connecting
the cable as described above. Please refer to the Wired Remote Installation Guide or
Diverter Installation Guide for the relevant wiring diagrams.
•
!
27
For concealed products, fit the shower head system following the installation
instructions overleaf, then proceed to point 31.
For exposed products continue with instructions 28-33.
28
Ensuring the hose washers are fitted at either end of the shower hose,
attach the hose to the male thread located underneath the controller.
Connect the power to the Quartz Smart Valve
™
and press the
‘Start/Stop’ button on the controller to turn the shower on.
Run the shower for 15 seconds to clear any debris and flush the
system through. Turn the shower off and isolate from the
electrical supply.
29
Thread the shower hose through the hose restraint.
30
To attach the handset to the hose, disengage the pivot clip from
the bottom of the handset by pressing the tab and pulling the pivot
hose connector clear. Ensure the hose washer is in the correct
position and screw the pivot hose connector into the hose.
Re-insert the pivot hose connector into the handset and push the
tab to lock into position, then place the handset into the Aqualisa
Pinch Grip
™
holder.
For both concealed and exposed systems please follow the remaining instructions.