BEFORE YOU START
This shower should be installed by a competent person in compliance with
current Water Supply Regulations. For further details contact your Local
Water Authority.
a. Identify all components and check pack contents.
b. Turn off the water supplies.
WATER SUPPLY REQUIREMENTS
Hot Water Maximum: 65˚C
Recommended 60-65˚C
Cold Water Minimum: 5˚C
Recommended 10-15˚C
Operating Pressure Range: Min. 0.2 bar, Max. 5.0 bar
Dream™ valves are suitable for gravity stored, gravity boosted, balanced
high pressure and combination boiler systems.
N.B. The combination boiler MUST have a minimum rating of 24kW
(80,000 Btu) and be of the type fitted with a fully modulating gas valve.
Boiler performance may affect outlet temperature.
Operating pressures on hot and cold supplies should be kept as even as
possible in order to ensure the maximum efficiency of the mixer.
When water pressure is higher than 5 bar, a pressure reducing valve (not
supplied) must be fitted before the mixer. A setting of 3 bar is recommended.
Before making any pipe connections all supplies MUST be
thoroughly flushed to remove any debris.