33
GENERAL MAINTENANCE
Cleaning the Filter
(if no flow, low flow rate or temperature inconsistency)
1. IMPORTANT Before carrying out any maintenance, ensure the water
supplies for the shower are isolated. Once isolated, turn the shower on
to release internal pressure. If unsure contact a qualified tradesman.
2. Remove the caps, unscrew the lever (where fitted) and loosen the grub
screws. Pull away the temperature and flow handles, then remove the
wall plate. Without removing the black temperature override stop,
unscrew and remove the temperature shroud ring.
3. Remove the filters using a 10mm Allen key, clean the filters by rinsing
thoroughly under cold water to remove any build up of limescale or
debris.
4. Refit the filters into the body and tighten using a 10mm Allen key.
Reinstate the water supply to ensure there are no leaks.
5. Refit the components in the reverse order of instruction 2.
Cap
Lever
Grub screw
Grub screw
Temperature
knob
Control knob
2.5mm Allen
key
Wall plate
10mm Allen key
Filters
Temperature shroud ring
Black temperature
override stop
Single outlet valve shown
for illustrative purposes.