24
4
Temporarily cap off the fixed arm, open the shower valve and check
for leaks.
Without rear access
Backnut washer
Backnut
Cover plate
Shower arm
Backnut washer
Backnut
Cover plate
Fixing nut
Shower arm
Backnut
Backnut washer
Fixing nut
Cover plate
Shower arm
Backnut washer
Backnut
Wall
Female fitting
(not supplied)
Wall
N.B. Square shower arm shown for illustrative purposes.
Without rear access
1
Run pipework from the shower valve to the desired location for the
fixed arm ensuring it terminates in a suitable ½” female connector
(not supplied). All pipework and connectors must be secured using
suitable fixings.
N.B. For round fixed wall arms only, fit the cover
plate and fixing nut (flat side of fixing nut facing the wall) to the
shower arm.
2
The backnut and backnut washer are not required. Wind the fixed
arm thread directly into the ½” female connector (not supplied) using
PTFE tape or similar, to achieve a watertight seal.
3
Temporarily cap off the fixed arm, open the shower valve and check
for leaks.