32
CARTRIDGE TEMPERATURE ADJUSTMENT
This product has been factory set under balanced pressures, and a hot
water supply of 65°C. If site conditions vary significantly from the factory
conditions, it may be necessary to reset the temperature of the cartridge
to enable the product to deliver 38°C when the temperature knob is set
to the 38°C position.
N.B. This product can reach temperatures of up to 55°C.
The cartridge can be adjusted to change the outlet water temperature to
suit your requirements. This is done by using a digital thermometer and
following the below instructions.
1. Turn the temperature knob to the 38°C position.
2. Carefully remove the cap, loosen the grub screw, then remove the
temperature knob.
3. Run the shower at required flow.
4. Whilst measuring the temperature of the water, and without removing
the black temperature override stop, turn the brass spindle until the
temperature reaches 38°C.
5. Once 38°C is achieved,
turn the shower off.
6. Depress the temperature
override safety button
and fit the temperature
knob into place with the
button at the 6 o’clock
position. Tighten the grub
screw and fit the cap.
N.B. Adjusting the pre-set
temperature will also adjust
the full hot setting.
Cap
Grub screw
Temperature
knob
Black temperature
override stop
Thermostatic
cartridge spindle
Temperature
shroud ring
Allen key