background image

DREAM

 CONCEALED 

THERMOSTATIC MIXER

INSTALLATION AND USER GUIDE

Summary of Contents for dream

Page 1: ...DREAM CONCEALED THERMOSTATIC MIXER INSTALLATION AND USER GUIDE ...

Page 2: ... 10 Components Bath Fill 12 Components Hand Shower Kits 12 Installation Valve 13 Installation Trim Pack 19 Installation Wall Outlets 21 Installation Wall Fixed Arms 23 Installation Fixed Heads 25 Installation Adjustable Rail Kits Round 25 Installation Adjustable Rail Kits Square 27 Installation Bath Fill 29 Installation Waste Pipe Extension where required 31 Cartridge Temperature Adjustment 32 Gen...

Page 3: ...o ensure that this product reaches you in perfect condition However should any parts be damaged or missing please contact your point of purchase This does not affect your statutory rights In addition if you require replacement parts please contact the Aqualisa customer helpline on 01959 560010 for assistance TOOLS REQUIRED Tools not supplied WARRANTY Aqualisa products are supplied complete with a ...

Page 4: ... for gravity stored gravity boosted balanced high pressure and combination boiler systems N B The combination boiler MUST have a minimum rating of 24kW 80 000 Btu and be of the type fitted with a fully modulating gas valve Boiler performance may affect outlet temperature Operating pressures on hot and cold supplies should be kept as even as possible in order to ensure the maximum efficiency of the...

Page 5: ...OWER KIT Page 12 DRMDCV1 AD RND Single DRMDCV1 AD SQR Single DRMDCV1 FW RND Single DRMDCV1 FW SQR Single DRMDCV2 ADFW RND Dual DRMDCV2 ADFW SQR Dual DRMDCV2 ADBTX RND Dual DRMDCV2 ADBTX SQR Dual DRMDCV3 ADFWBTX RND Triple DRMDCV3 ADFWBTX SQR Triple DRMDCV2 HSFW RND Dual DRMDCV2 HSFW SQR Dual PRODUCT COMPONENT LISTS ...

Page 6: ... Filter Allen Key 1 1 4 5 3 6 2 VALVE BODY DUAL OUTLET NO DESCRIPTION QTY 1 Wall Plugs 2 2 Wall Screws 2 3 Valve Body 1 4 Copper Olives 4 5 Compression Nuts 4 6 10mm Filter Allen Key 1 1 4 5 3 6 2 VALVE BODY TRIPLE OUTLET NO DESCRIPTION QTY 1 Wall Plugs 2 2 Wall Screws 2 3 Valve Body 1 4 Copper Olives 5 5 Compression Nuts 5 6 10mm Filter Allen Key 1 1 4 5 3 6 2 ...

Page 7: ...Ring 1 8 Temperature Shroud Ring 1 9 Wall Plate 1 N B Pack will contain either 7a or 7b COMPONENTS SINGLE AND DUAL TRIM PACKS TRIM PACK SQUARE NO DESCRIPTION QTY 1 2 5mm Allen Key 1 2 Cap 2 3 Grub Screw 2 4 Control Knob 1 5 Temperature Knob 1 6a Single Control Shroud Ring 1 6b Dual Control Shroud Ring 1 7 Temperature Shroud Ring 1 8 Wall Plate 1 N B Pack will contain either 6a or 6b 6b 7 8 6a 1 2 ...

Page 8: ...nob 2 5 Temperature Knob 1 6 Cap 1 7 Wall Plate 1 8 Bottom Shroud Ring 1 9 Temperature Shroud Ring 1 10 Top Shroud Ring 1 TRIM PACK SQUARE NO DESCRIPTION QTY 7 8 9 6 2 3 4 2 3 4 1 5 2 3 1 2 5mm Allen Key 1 2 Grub Screw 3 3 Cap 3 4 Control Knob 2 5 Temperature Knob 1 6 Wall Plate 3 7 Bottom Shroud Ring 1 8 Temperature Shroud Ring 1 9 Top Shroud Ring 1 ...

Page 9: ...1 4 Shower Arm 1 5 Filter Washer 1 6 Ball Joint 1 7 Shower Head 1 1 2 4 5 6 7 3 FIXED HEAD AND ARM ROUND NO DESCRIPTION QTY 1 Backnut 1 2 Backnut Washer 1 3 Fixing Nut 1 4 Cover Plate 1 5 Shower Arm 1 6 Filter Washer 1 7 Ball Joint 1 8 Shower Head 1 6 7 8 1 2 3 4 5 COMPONENTS WALL FIXED HEADS ...

Page 10: ... 11 4 1 12 14 13 15 1 Wall Plug 2 2 Upper Rail Bracket 1 3 Wall Screw Short 1 4 Rail End Cap 2 5 Pinch grip Holder 1 6 Gel Hook 1 7 Harmony Handset 1 8 Riser Rail 1 9 Shower Hose 1 5m 1 10 Lower Rail Bracket 1 11 Wall Screw Long 1 12 Backnut 1 13 Backnut Washer 1 14 Wall Cover Plate 1 15 Wall Outlet 1 ...

Page 11: ...8 5 2 1 4 3 13 11 12 10 1 2 6 3 5 4 1 Rail End Cover 2 2 Rail Bracket 2 3 Wall Plug 2 4 Wall Screw 2 5 Cover Plate 2 6 Handset Holder 1 7 Riser Rail 1 8 Handset 1 9 Shower Hose 1 5m 1 10 Wall Outlet 1 11 Wall Cover Plate 1 12 Backnut Washer 1 13 Backnut 1 ...

Page 12: ...2 COMPONENTS HAND SHOWER KITS HAND SHOWER KITS NO DESCRIPTION QTY 1 2 3 3 5a 6 5b 4a 1 2 4b 1 Backnut 1 2 Backnut Washer 1 3 Wall Cover Plate 1 4a Wall Outlet Round 1 4b Wall Outlet Square 1 5a Hand Shower Round 1 5b Hand Shower Square 1 6 1 5m Smooth Hose 1 N B Pack will contain either 4a and 5a or 4b and 5b ...

Page 13: ...r nuts INSTALLATION VALVE DUAL OUTLET Hot water inlet Cold water inlet 15mm pipework Outlet 1 Fixed head or bath fill Outlet 2 Adjustable head or hand shower Valve body Copper olives Compression nuts Wall plugs Filter nuts Wall screws IMPORTANT Ensure outlet feeds are configured as per the diagram shown Fixed head or bath fill Left outlet Adjustable head or hand shower Right outlet ...

Page 14: ...crews Wall plugs Outlet 2 Adjustable head or hand shower Outlet 1 Fixed head IMPORTANT Ensure outlet feeds are configured as per the diagram shown Fixed head Left outlet Adjustable head or hand shower Right outlet Bath fill Bottom outlet 1 Turn off the water supply prior to installation Prepare the recess in the wall for the valve body and pipework ...

Page 15: ...0 126 18 70 200 178 69 90 36 5 All sizes shown are in millimetres Valve concealing depth is from the back of the valve to the wall plate min 69mm max 90mm 71 5 130 126 18 70 200 178 69 90 36 5 71 5 130 126 18 70 200 178 69 90 36 5 N B Dual outlet valve shown for illustrative purposes Refer to page 16 for triple outlet valve ...

Page 16: ...69mm Min Max Concealing Plate adjustment 69 90mm See below dimension drawing 71 5 130 126 18 70 70 280 178 69 90 36 5 All sizes shown are in millimetres Valve concealing depth is from the back of the valve to the wall plate min 69mm max 90mm ...

Page 17: ...1 on the valve body The adjustable head outlet pipe connects to the right outlet Outlet 2 on the valve body The bath fill outlet pipe connects to the bottom outlet Outlet 3 on the valve body For all models Ensure sufficient pipe length the pipe ends insert into the valve inlets and outlet s a minimum of 10mm 3 Connect the valve loosely to the pipework do not tighten 4 Hold the valve in position in...

Page 18: ...re left accessible plasterboard and tile the cavity wall ensuring there is an adequate gap between the tiles and the valve body To allow for any future maintenance an access hole is required Single and Dual models 120mm high x 110mm wide Triple outlet models 190mm high x 110mm wide ...

Page 19: ...oud ring N B Round triple outlet valve shown for illustrative purposes Refer to page 7 for single and dual model trim packs 1 Isolate the water supplies to the shower Remove the cover screws and black covers from the valve 2 Screw the shroud rings into place do not overtighten 3 Apply a bead of silicone sealant to the rear of the wall plate and carefully push the wall plate into position flush wit...

Page 20: ... grub screw and fit the cap 7 For single outlet To fit the top control knob ensure the brass on off spindle is in the off position turned fully clockwise Unscrew and remove the lever or cover cap from the control knob and loosen the grub screw located in the control knob Fit the control knob to the on off spindle with the grub screw and lever hole positioned to OFF 12 o clock Tighten the grub scre...

Page 21: ...b screw and refit the lever or cover cap 8 Reinstate water supplies and test INSTALLATION WALL OUTLETS Backnut washer Backnut Wall Wall outlet Cover plate Female fitting not supplied Wall Wall outlet Cover plate With rear access Without rear access see page 22 Backnut washer Backnut Wall Wall outlet Cover plate Female fitting not supplied Wall Wall outlet Cover plate N B Round wall outlet shown fo...

Page 22: ...en the shower valve and check for leaks Without rear access 1 Run pipework from the shower valve to the desired location for the wall outlet ensuring it terminates in a suitable female connector not supplied All pipework and connectors must be secured using suitable fixings 2 The backnut and backnut washer are not required Wind the wall outlet thread directly into the female connector not supplied...

Page 23: ...terminates in a suitable female connector not supplied All pipework and connectors must be secured using suitable fixings N B For round fixed wall arms only fit the cover plate and fixing nut flat side of fixing nut facing the wall to the shower arm 2 Feed the fixed arm thread through a 22 28mm hole in the wall and secure with the backnut ensuring the backnut washer is fitted between the backnut a...

Page 24: ...ower valve to the desired location for the fixed arm ensuring it terminates in a suitable female connector not supplied All pipework and connectors must be secured using suitable fixings N B For round fixed wall arms only fit the cover plate and fixing nut flat side of fixing nut facing the wall to the shower arm 2 The backnut and backnut washer are not required Wind the fixed arm thread directly ...

Page 25: ... is in the correct position attach the fixed head to the fixed arm by screwing the ball joint into place 2 Open the shower valve and check for leaks INSTALLATION ADJUSTABLE RAIL KIT ROUND Refer to page 27 for square kit 1 The top bracket is a floating bracket and can be positioned to suit existing screw holes if required Prepare two fixing points using the fixings provided if suitable N B The maxi...

Page 26: ...d wall surface using the short wall screw provided if suitable 4 Attach the lower rail bracket onto the bottom of the rail 5 Slide the rail assembly up through the upper rail bracket 6 Align the fixing hole of the bottom bracket with the corresponding holes on the rail assembly ensuring the smaller sized hole on the rail is closest to the wall Secure the bottom rail bracket to the wall using the l...

Page 27: ... handset and secure the handset to the hose Place the handset into the handset holder INSTALLATION ADJUSTABLE RAIL KIT SQUARE Refer to page 25 for round kit 1 Prepare two fixing points at 700 740mm using the fixings provided if suitable N B Ensure that the hose will not be over extended when the slider is at its highest position 530 mm 1 1 3 0 m m 700 740mm 2 Insert a screwdriver or similar tool i...

Page 28: ...k correctly 5 Slot the grey rail brackets into the rail and place the assembly on the wall lining up the fixing points secure to the wall 6 Slide the rail end covers onto the brackets until they click into place 7 Ensuring the hose washer is in the correct position attach the hose to the wall outlet Run the shower for a few seconds to clear any debris that may be present wall outlet installation i...

Page 29: ...remove the bath waste clicker assembly from the waste body and set aside 2 1 2 1 3 Offer the bath waste into position ensuring the rubber washer is correctly aligned between the waste assembly and the bath base 4 Ensuring the rubber washer is correctly aligned pass the bath waste clicker through the bath and secure to the waste body assembly 2 1 ...

Page 30: ...orrectly aligned pass the overflow filler outlet through the bath and secure to the body assembly 8 Remove the relevant inlet blanking plug and attach the flexible hose to the blended inlet connection IMPORTANT PTFE thread tape or similar MUST be used to guarantee a watertight seal 9 Connect the flexible hose to the blended supply pipe ensuring a suitable non restrictive double check valve not sup...

Page 31: ...nut and remove the waste pipe from the waste assembly 2 Remove the clamping nut and sealing washer from the waste pipe and set aside 3 Carefully cut down the length of the waste pipe and disconnect from the outlet assembly ensuring not to damage the outlet 4 To reassemble push the longer waste pipe into position over the outlet and secure it in place using a jubilee clip not supplied N B The waste...

Page 32: ...ow instructions 1 Turn the temperature knob to the 38 C position 2 Carefully remove the cap loosen the grub screw then remove the temperature knob 3 Run the shower at required flow 4 Whilst measuring the temperature of the water and without removing the black temperature override stop turn the brass spindle until the temperature reaches 38 C 5 Once 38 C is achieved turn the shower off 6 Depress th...

Page 33: ...thout removing the black temperature override stop unscrew and remove the temperature shroud ring 3 Remove the filters using a 10mm Allen key clean the filters by rinsing thoroughly under cold water to remove any build up of limescale or debris 4 Refit the filters into the body and tighten using a 10mm Allen key Reinstate the water supply to ensure there are no leaks 5 Refit the components in the ...

Page 34: ...erature override stop from the cartridge and remove the cartridge retaining nut using a suitable spanner Remove and clean the cartridge by rinsing thoroughly under cold water to remove any build up of limescale or debris 4 If necessary replace the cartridge A replacement cartridge can be obtained by contacting customer service on 01959 560010 5 Refit the cartridge into the valve body tighten the c...

Page 35: ...lly and immerse in a mild proprietary descaler IT IS IMPERATIVE THAT DESCALING IS CARRIED OUT STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS SUBSTANCES THAT ARE NOT SUITABLE FOR PLASTICS AND ELECTROPLATED SURFACES MUST NOT BE USED USER GUIDE Flow control Single outlet valves 1 The lever or cover cap in the 12 o clock position indicates the valve is fully closed When the lever or cover ...

Page 36: ...e temperature control to select a comfortable showering temperature using the temperature markings as a guide IMPORTANT The temperature stop button should be pressed to allow for a warmer setting N B As with many of the Aqualisa shower valves fitted to combination boiler systems it may be necessary to adjust the flow control knob and reduce the flow to achieve a comfortable showering temperature S...

Page 37: ...select the desired spray pattern When the lever is in position d the water saving Eco mode is selected This provides the same spray pattern as position c but depending on which water system the product is fitted to offers up to 25 water saving a Inner b Middle c Outer d Eco To remove the shower head depress the anti swivel locking button on the handset and unscrew the hose Square The shower head h...

Page 38: ...pressure changes or instantaneous boiler temperature changes Do not use other water outlets when using the shower Make sure the maintained inlet pressures are nominally balanced and sufficient Refer to Water Supply Requirements page 4 Airlock or partial blockage of the pipework gravity supply only Flush through pipework to ensure removal of debris and any airlocks No hot or cold water reaching the...

Page 39: ...tion page 33 Installation conditions outside operating parameters Refer to Water Supply Requirements page 4 Refer to Cleaning the Thermostatic Cartridge section page 34 Refer to Cartridge Temperature Adjustment page 32 Hot water temperature is less than 10 c above the required blend temperature Adjust hot water temperature or wait for water to reheat if stored system is used Instantaneous water he...

Page 40: ... aqualisa co uk Email enquiries aqualisa co uk Warranty www aqualisa co uk warranty Republic of Ireland Sales enquiries 01 864 3363 Service enquiries 01 844 3212 Part No 705351 Issue 01 Feb 21 Please note that calls may be recorded for training and quality purposes The company reserves the right to alter change or modify the product specifications without prior warning Trademark of Aqualisa Produc...

Reviews: