4. When the feed water temperature has dropped below 40°C the interrupting and restoring the
power supply should result in bacteria flushing and auto-restore to standby.
NOTE:
High feed water temperatures lead to a significantly increased deterioration of the membrane,
but does not influence the quality of the water produced.
Servicing the system
PRE-FILTRATION INSERTS
The replacement intervals are dependent on the degree of water contamination and total quantity
produced by the system and should be replaced at least every six month in order to protect
the membrane. To keep track of the replacement intervals it is advised to keep a record of the
replacements.
HOW TO REPLACE THE PRE-FILTRATION INSERTS
1.
Disconnect the power supply. Close off the feed water supply.
Depressurise the pre-filter housings by opening the vent plugs (See Fig. 1a).
The filtration inserts are fitted inside the plastic bowls fitted to the pre filter unit.
2.
Access to the filtration inserts is gained by removing the locking ring that holds the
transparent filter container by rotating it clockwise.
3.
Carefully remove the plastic container with the insert in it and empty the water out in the
sink. Place a bucket underneath the pre-filter unit to avoid spillage.
4.
Remove the filter insert and clean the inside of the transparent container with water.
5.
Unpack the new filter insert, and place in the container. The particle filter can be fitted
with either side up, the carbon filter (black) needs to be fitted with the seal on one end
pointing upwards as shown in figure 1b on page 4.
6.
Place the plastic container holding the new filter insert back in its original location and
tighten the assembly with the locking ring that holds the transparent filter container by
rotating it counter clockwise.
7.
Open the feed water supply again.
Make sure both vent plugs on the filtration housing are (still) open, and let air trapped in the filter
run out, until water without any air comes from the ventilation holes.
8.
Close both vent plugs by hand force only.
9.
Check for possible leaks resulting from changing the membrane.
10.
When no leaks are observed, initiate a commissioning procedure.
11.
The machine is ready for normal use again.
MINERAL CARTRIDGE EXCHANGE AND RESET
1.
Disconnect the power supply.
2.
Open the faucet until the water stops flowing.
3.
Click out the existing mineral cartridge replace it with the new cartridge. Be aware some
water may come out.
4.
Check if the tap is still open.
5.
Connect the power supply again. The system will directly perform a flush. To reset the
remin counter in the machine, please click the black button at the back of the machine, 3
times within 1 second.
6.
Let the faucet run for 2 minutes then close the faucet.