![Aquablu One Manual Download Page 38](http://html.mh-extra.com/html/aquablu/one/one_manual_2959378038.webp)
Innovative purification solutions
www.aquablu.com
37
Decommissioning the system
At the end of its serviceable life, the system as whole or individual parts that have become unser-
viceable must be decommissioned and discarded in a responsible manner. The system is simply
decommissioned by disconnecting it first from the mains electricity supply, then from the mains
water supply. Empty the system, and take out the filter cartridges and the membranes, and dis-
card these separately. Most of the materials and assemblies used in the system can be recycled
due to their design and the materials used. Take the system or the involved part(s) to the munici-
pal/district recycling yard, a commercial recycling company, or return the system to the dealer
who will take care of this.
Technical Data
The system is designed to operate within the limits listed in the table below:
Max. Operating pressure
6 bar
Minimum ambient temperature
+5°C
Maximum ambient temperature
+45°C
Maximum feed water temperature
+45°C
Chlorine concentration
< 0,1 ppm
Water Turbidity
1 NTU
Max. TDS** inlet water at membrane
< 1200 ppm*** (2500 uS/cm****)
Max. TDS** inlet water at pre-filter
Depending on pre-filter configuration
Minimum Input Pressure
1,5 bar
Maximum Input pressure
3 bar
Purified water volume at 25°C
50 to 120 liters a hour
Max. Hardness
180 mg CaCO3/L or 10°DH
*NTU = Nephelometric Turbidity Units
**TDS = Total Dissolved Solids
*** PPM = Parts per million
**** uS/cm = Microsiemens per centimeter
Warranty Card & Serial Number:
Manual version:
1001