V:1.0
Copyright © 2014 Aqua Creek Products All Rights Reserved
Revised 12/11/14
V:1.0
Anchor Installation: New Construction or
Retro-Fit by Saw-Cutting
1.
Mask the bottom hole of the anchor sleeve to prevent concrete from seeping in.
2.
Install rebar in the 3’-9” x 3’-9” section of the deck that will be thickened to 10”.
SEE FIGURES A & B
3.
Set the bronze anchor sleeve in place. Make sure the center of the anchor sleeve
is no more than 36” from the pool’s edge. Set the fixing anchor insert 7 1/2” from
the center of the anchor sleeve. Fixing anchor may be located anywhere on the
deck, as long as it is 7 1/2” from the center of the anchor sleeve. SEE FIGURE A
4.
Bond the anchor sleeve according to your local code requirements by using the
bonding lug and bonding screw on the side of the anchor sleeve.
5.
Pour your concrete and finish the pool deck surface.
6.
Once the concrete has cured, your lift is ready to be mounted into the anchor
sleeve.
3'-9"
(MIN.)
ASSEMBLY
2.19" O.D. X 6"
BRONZE ANCHOR
7 1/2"
3'-9"
(MIN.)
7" MIN
(24" MAX)
22 1/2"
22 1/2"
12"
MIN
19" MIN
(36" MAX)
1-1/2" MIN
(FIXING-ANCHOR)
POOL
WALL
10"
6"
4"
7 1/2"
3"
CLR
2"
CLR
BONDING LUG:BOND PER LOCAL CODE
2.19 O.D. X 6" BRONZE ANCHOR ASSEMBLY
1" x 4" PVC "FIXING-ANCHOR"
3'-9" SQ. X 10" DEEP CONC. FTG.
W/ 4-#4 E.W., TOP & BTTM.
DRILLING AND EPOXYING REBAR TO EXISTING SLAB
(4" MIN. EMBED W/ HILTI RE500 SD OR SIMPSON SET-XP EPOXY)
IS RECOMMENDED TO RESIST DIFFERENTIAL MOVEMENTS
8-AWG SOLID COPPER WIRE (TO BONDING GRID)
FIGURE A
FIGURE B
5