background image

AQUASTREAM ULTIMATE

16.4.

16.4.

16.4.

16.4. Additional features (aquasuite only)

Additional features (aquasuite only)

Additional features (aquasuite only)

Additional features (aquasuite only)

Two additional feature are available for the aquastream ULTIMATE, the advanced
controller  package  and the  virtual flow  sensor  extension.  After initial operation,
both features are activated for a trial period of 48 hours of operation. The features
are deactivated after  expiration  of this trial period, but can  be permanently en-
abled at any time by purchasing a software key. To buy a key, please click one of
the buttons in the aquasuite software, you will be redirected to a corresponding
web portal on our website (internet connection required).
After having received a key file, you can simply drag&drop this file from your email
program or file system to the “activate function” button, or click the button and se-
lect the file manually. The new features are immediately activated. 

16.5.

16.5.

16.5.

16.5. Firmware update and language selection (aquasuite only)

Firmware update and language selection (aquasuite only)

Firmware update and language selection (aquasuite only)

Firmware update and language selection (aquasuite only)

The most up to date firmware for all supported devices is always included in the
current version of the aquasuite software. The button “ Update firmware now” will
start the update process for the device firmware. 
During the firmware update process, the language of the pump menu will auto-
matically be set to the currently selected language in the aquasuite software. To
change the language of the pump menu, first select the desired language in the
basic aquasuite settings and restart the aquasuite software. Afterwards, perform a
firmware   update  of   the   aquastream   ULTIMATE   to   change   the   language   of   the
pump. 
During the firmware update  process,  do not disconnect the device  from the PC
and do not power down the PC! After the firmware is successfully updated, the
aquasuite software will be automatically closed.

17.

17.

17.

17. aquasuite web

aquasuite web

aquasuite web

aquasuite web

Click the entry “aquasuite web” to publish data on the internet or import data from
the internet. The server for this service is operated by Aqua Computer and provid-
ed for use with the aquasuite, without warranty for for error free operation or per-
manent availability. Aqua Computer reserves the right to limit or cancel this service
at any time. 

17.1.

17.1.

17.1.

17.1. Data export

Data export

Data export

Data export

To publish data, create a new export data set by clicking the plus symbol in the
upper right corner of the “Data export” window. The name of the data set may be
modified to meet your requirements. You may then add the data sources to export
by clicking the plus symbol in the “Data sources” window section. By clicking the
gear symbol,  the name of the  corresponding value can be changed.  Up to 30
data sources can be added to each export data set, the total number of export

- 24 -

Aqua Computer GmbH & Co. KG

© 2016-2018

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Summary of Contents for aquastream ULTIMATE

Page 1: ...nd installation manual aquastream ULTIMATE aquasuite version 2018 Current as of October 2018 All information contained in this manual is subject to change without prior notice All rights reserved 2016...

Page 2: ...n 9 8 aquasuite software 9 8 1 Installation of the aquasuite software 9 8 2 Basic operation 10 8 3 Symbols in the headlines 10 9 Overview pages aquasuite 11 9 1 Desktop mode 11 9 2 Creating new overvi...

Page 3: ...ensor configuration 21 14 1 External flow sensor 21 14 2 Virtual flow sensor software extension Virtual Flow Sensor only 21 14 3 Offsets for temperature sensors 21 14 4 Software temperature sensors Ad...

Page 4: ...e to be observed at all times Read this manual thoroughly and entirely Save your data onto suitable media before working on your hardware The pump must not be placed under water The pump controller on...

Page 5: ...ump 5 5 5 5 Assembly instructions Assembly instructions Assembly instructions Assembly instructions Install connecting adapters not included in delivery to the aquastream ULTIMATE The adapters should...

Page 6: ...ou are having trouble to connect Pin assignment Pin 1 2 3 7 8 9 11 not connected Pin 4 5 6 10 12 GND Pin 13 14 15 12 V DC 6 3 6 3 6 3 6 3 Connector USB Connector USB Connector USB Connector USB This c...

Page 7: ...or the switching signal can be activated in case of an alarm condition for configuration see chapter 13 2 For example the aquabus speed signal cable in cluded in delivery can be used to connect this h...

Page 8: ...on of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE 7 1 7 1 7 1 7 1 Initial operation Initial operation Initial...

Page 9: ...isplay the aquasuite software should be closed on a connected PC Otherwise the aquasuite will overwrite and thereby cancel any settings made on the device itself 7 3 7 3 7 3 7 3 Configuration using US...

Page 10: ...icking the arrow symbol in the upper left corner List elements may be minimized or maximized for easier access by clicking the title bar The title bars may contain various symbols that will be explain...

Page 11: ...uasuite window for editing and the current desktop will be displayed as background for your convenience 9 2 9 2 9 2 9 2 Creating new overview pages and activating edit mode Creating new overview pages...

Page 12: ...vailable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chro...

Page 13: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Page 14: ...n the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure the log settings as described in the chapter Log settings of this manual Se...

Page 15: ...Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are available you will have to configure the log settings as described in the chapter Log...

Page 16: ...eset speed preset If speed preset mode is selected you can manually set the desired rotation speed of the pump If the selected speed cannot be attained the pump controller will use the highest stable...

Page 17: ...om level for this axis a double click into the diagram will reset both axes Selecting an area on an axis will zoom this axis to this area selecting an area in the diagram will zoom both axes to this a...

Page 18: ...ent corresponding to the current temperature is scaled to the range between minimum and maximum fan power settings before being ap plied to the fan output The startup temperature will also be factored...

Page 19: ...tput range can be limited by setting Minimum power and Maximum power values correspondingly The check box Hold minimum power determines whether the fan will be switched off during a power setting of 0...

Page 20: ...t up but are not active presently are highlighted with a yel low background color Make sure only to use readings for alarm evaluation that are functional with your specific setup 13 4 13 4 13 4 13 4 S...

Page 21: ...y 10 Flow rates below 40 l h will not be displayed due to increasing imprecision of the calculation method for low flow rates Limitations Flow rate can not be calculated if a second pump is present in...

Page 22: ...r temperature sensor selection Water temperature sensor selection Select one of the available temperature sensors to be displayed as Water temper ature in the information pages on the pump display Thi...

Page 23: ...up port You may enter a Device description for easier identification this text will be displayed in the device list and in the data quick view 16 2 16 2 16 2 16 2 Factory defaults Factory defaults Fac...

Page 24: ...rmware update process the language of the pump menu will auto matically be set to the currently selected language in the aquasuite software To change the language of the pump menu first select the des...

Page 25: ...m the transmitted data suitable to be included in forums signatures The code required for the Aqua Computer forums is provided for your convenience 17 3 17 3 17 3 17 3 Data import Data import Data imp...

Page 26: ...lowing annual ver sion For software activation at least one device in the computer must contain a corresponding license If a valid license is detected for at least one device all de vices connected to...

Page 27: ...ess ing the middle key 3 Turn off the PC Press and hold the middle key and turn on the PC Release the key once pump data is displayed 19 2 19 2 19 2 19 2 Replacement parts Replacement parts Replacemen...

Page 28: ...his device has to be disposed of as electronic waste Please check your local regulations for disposal of electronic waste 20 4 20 4 20 4 20 4 Contact Aqua Computer Contact Aqua Computer Contact Aqua C...