AQUASTREAM ULTIMATE
●
Mouse movement while right button is pressed will move the displayed area
of the diagram.
12.5.
12.5.
12.5.
12.5. Fan mode two point controller (Advanced Controller Package only)
Fan mode two point controller (Advanced Controller Package only)
Fan mode two point controller (Advanced Controller Package only)
Fan mode two point controller (Advanced Controller Package only)
The two point controllers mode will result in switching the fan output on and off
when the temperature reading of the selected temperature sensor rises above/falls
below predefined values.
12.6.
12.6.
12.6.
12.6. Fan settings
Fan settings
Fan settings
Fan settings
Depending on currently selected fan mode, additional parameters can be config-
ured.
In voltage controlled mode (for conventional 3-pin fans), output voltage is adjust-
ed to control the fan. In PWM mode (for 4-pin PWM fans), a PWM signal is gener-
ated and adjusted on the dedicated PWM pin, output voltage is set to 12 V.
The start boost feature can be used to reliably power up a fan or pump connected
to the output. If activated, the aquastream ULTIMATE controller will set the fan out-
put to the 100 % power for a short duration before switching to normal operation
whenever the output power changes from exactly 0 % setting to a higher value.
The fan output range can be limited by setting “Minimum power” and ”Maximum
power” values correspondingly. The check box “Hold minimum power” determines
whether the fan will be switched off during a power setting of 0 % (box not
checked) or remain active at the set minimum speed (box checked). Set minimum
power to a value at which the connected fan reliably starts up.
The “Maximum rotation speed of connected fan” setting applies only to diagram
scaling within the aquasuite and has no effect on the fan output.
13.
13.
13.
13. Alarm configuration
Alarm configuration
Alarm configuration
Alarm configuration
aquasuite: Select “Alarms” from the device list below the “aquastream ULTIMATE”
entry.
Device menu: Select “Alarms” from the menu list and confirm by pressing the mid-
dle key.
13.1.
13.1.
13.1.
13.1. Acoustic alarm
Acoustic alarm
Acoustic alarm
Acoustic alarm
This parameter determines whether the alarm buzzer will activated during alarm
conditions. The alarm buzzer is always active for non-configurable systems alarms
regardless of this setting.
13.2.
13.2.
13.2.
13.2. RPM header function
RPM header function
RPM header function
RPM header function
Select the signal to be provided through the speed signal output:
●
Speed signal disabled during alarm: A speed signal is generated as long as
no alarm condition is detected. Allows for alarm monitoring if RPM header
of the pump is connected to a fan header with speed signal monitoring.