background image

AQUASTREAM ULTIMATE

18.5. License manager.......................................................................26

19. Troubleshooting........................................................................27

19.1. Restore factory defaults..............................................................27
19.2. Replacement parts....................................................................27

20. Technical details and care instructions........................................27

20.1. Technical details.......................................................................27
20.2. Care instructions.......................................................................28
20.3. Waste disposal.........................................................................28
20.4. Contact Aqua Computer............................................................28

1.

1.

1.

1. Preface

Preface

Preface

Preface

The aquastream ULTIMATE pump is built for longevity and to match the highest
quality standards. It has been particularly designed for PC water cooling systems.
Each pump is meticulously submitted to a test run; therefore you might find some
moist residues within the pump.
Considering the fast technical development, we reserve the right to perform alter-
ations to the products at any time. It therefore is possible that your product does
not correspond precisely to the descriptions  or especially the illustrations  in this
manual.

2.

2.

2.

2. Safety precautions

Safety precautions

Safety precautions

Safety precautions

The following safety precautions have to be observed at all times:

Read this manual thoroughly and entirely!

Save your data onto suitable media before working on your hardware!

The pump must not be placed under water!

The pump controller on the rear end of the pump must not get in contact
with water!

The pump may only be used inside a PC case!

A short rattle noise upon start-up is normal. If the noise persists for a longer
period of time, there might still be some air inside the pump chamber.

The pump is not a suction pump. Make sure the pump chamber is filled with
water prior to operation!

The pump must never be operated without the rotor! For rotor replacement,
only the Aqua Computer rotor with order code 41065 may be used!

The pump is not suited for dry operation!

Operate only indoors. Not suited for outdoor operation!

This product is not designed for use in life support appliances, devices, or
systems where malfunction of this product can reasonably be expected to re-
sult in personal injury. Aqua Computer GmbH & Co. KG customers using or
selling this product for use in such application do so at their own risk and

- 4 -

Aqua Computer GmbH & Co. KG

© 2016-2018

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Summary of Contents for aquastream ULTIMATE

Page 1: ...nd installation manual aquastream ULTIMATE aquasuite version 2018 Current as of October 2018 All information contained in this manual is subject to change without prior notice All rights reserved 2016...

Page 2: ...n 9 8 aquasuite software 9 8 1 Installation of the aquasuite software 9 8 2 Basic operation 10 8 3 Symbols in the headlines 10 9 Overview pages aquasuite 11 9 1 Desktop mode 11 9 2 Creating new overvi...

Page 3: ...ensor configuration 21 14 1 External flow sensor 21 14 2 Virtual flow sensor software extension Virtual Flow Sensor only 21 14 3 Offsets for temperature sensors 21 14 4 Software temperature sensors Ad...

Page 4: ...e to be observed at all times Read this manual thoroughly and entirely Save your data onto suitable media before working on your hardware The pump must not be placed under water The pump controller on...

Page 5: ...ump 5 5 5 5 Assembly instructions Assembly instructions Assembly instructions Assembly instructions Install connecting adapters not included in delivery to the aquastream ULTIMATE The adapters should...

Page 6: ...ou are having trouble to connect Pin assignment Pin 1 2 3 7 8 9 11 not connected Pin 4 5 6 10 12 GND Pin 13 14 15 12 V DC 6 3 6 3 6 3 6 3 Connector USB Connector USB Connector USB Connector USB This c...

Page 7: ...or the switching signal can be activated in case of an alarm condition for configuration see chapter 13 2 For example the aquabus speed signal cable in cluded in delivery can be used to connect this h...

Page 8: ...on of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE 7 1 7 1 7 1 7 1 Initial operation Initial operation Initial...

Page 9: ...isplay the aquasuite software should be closed on a connected PC Otherwise the aquasuite will overwrite and thereby cancel any settings made on the device itself 7 3 7 3 7 3 7 3 Configuration using US...

Page 10: ...icking the arrow symbol in the upper left corner List elements may be minimized or maximized for easier access by clicking the title bar The title bars may contain various symbols that will be explain...

Page 11: ...uasuite window for editing and the current desktop will be displayed as background for your convenience 9 2 9 2 9 2 9 2 Creating new overview pages and activating edit mode Creating new overview pages...

Page 12: ...vailable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chro...

Page 13: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Page 14: ...n the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure the log settings as described in the chapter Log settings of this manual Se...

Page 15: ...Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are available you will have to configure the log settings as described in the chapter Log...

Page 16: ...eset speed preset If speed preset mode is selected you can manually set the desired rotation speed of the pump If the selected speed cannot be attained the pump controller will use the highest stable...

Page 17: ...om level for this axis a double click into the diagram will reset both axes Selecting an area on an axis will zoom this axis to this area selecting an area in the diagram will zoom both axes to this a...

Page 18: ...ent corresponding to the current temperature is scaled to the range between minimum and maximum fan power settings before being ap plied to the fan output The startup temperature will also be factored...

Page 19: ...tput range can be limited by setting Minimum power and Maximum power values correspondingly The check box Hold minimum power determines whether the fan will be switched off during a power setting of 0...

Page 20: ...t up but are not active presently are highlighted with a yel low background color Make sure only to use readings for alarm evaluation that are functional with your specific setup 13 4 13 4 13 4 13 4 S...

Page 21: ...y 10 Flow rates below 40 l h will not be displayed due to increasing imprecision of the calculation method for low flow rates Limitations Flow rate can not be calculated if a second pump is present in...

Page 22: ...r temperature sensor selection Water temperature sensor selection Select one of the available temperature sensors to be displayed as Water temper ature in the information pages on the pump display Thi...

Page 23: ...up port You may enter a Device description for easier identification this text will be displayed in the device list and in the data quick view 16 2 16 2 16 2 16 2 Factory defaults Factory defaults Fac...

Page 24: ...rmware update process the language of the pump menu will auto matically be set to the currently selected language in the aquasuite software To change the language of the pump menu first select the des...

Page 25: ...m the transmitted data suitable to be included in forums signatures The code required for the Aqua Computer forums is provided for your convenience 17 3 17 3 17 3 17 3 Data import Data import Data imp...

Page 26: ...lowing annual ver sion For software activation at least one device in the computer must contain a corresponding license If a valid license is detected for at least one device all de vices connected to...

Page 27: ...ess ing the middle key 3 Turn off the PC Press and hold the middle key and turn on the PC Release the key once pump data is displayed 19 2 19 2 19 2 19 2 Replacement parts Replacement parts Replacemen...

Page 28: ...his device has to be disposed of as electronic waste Please check your local regulations for disposal of electronic waste 20 4 20 4 20 4 20 4 Contact Aqua Computer Contact Aqua Computer Contact Aqua C...

Reviews: